ULTIMUM™ 407655Recalls & reported problems

St. Jude Medical, Inc. · HEMOSTASIS INTRODUCER · Class 2

All models of ULTIMUM (21)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05414734011259), received between Sep 6, 2019 and May 15, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak1
  • Material Fragmentation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 15, 2025Fluid/Blood Leak; Fluid/Blood Leak

    DURING A PROCEDURE, WITH A CATHETER INSERTED INTO THE SHEATH, A LEAK WAS NOTED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22029108 ↗
  • MalfunctionSep 6, 2019Material Fragmentation; Material Fragmentation

    DURING THE PROCEDURE, A PIECE OF THE DEVICE BROKE OFF AFTER BEING INSERTED INTO THE PATIENT'S ANATOMY. THE FEMORAL VEIN WAS DIFFICULT TO PUNCTURE AND A STIFF GUIDEWIRE WAS USED TO INTRODUCE THE INTRODUCER. WHEN THE DILATOR WAS REMOVED FROM THE PATIENT, THE TIP WAS NOTED TO BE SPLIT AND BROKEN AND A PIECE OF THE DEVICE WAS MISSING. THE MISSING PIECE WAS UNABLE TO BE FOUND AND IT WAS UNKNOWN IF THE DEVICE BROKE INSIDE THE PATIENT'S ANATOMY. THE DEVICE WAS REPLACED WITH NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8971537 ↗