Epic™ E100-23A-00Recalls & reported problems
St. Jude Medical, Inc. · St. Jude Medical Porcine Aortic Bioprosthetic Heart Valve · Class 3 · Implant
All models of Epic (26)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05414734055536), received between Dec 16, 2020 and Dec 16, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Deformation1
- Obstruction of Flow1
- Off-Label Use1
Patient problems
- Stenosis1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 16, 2020Off-Label Use; Obstruction of Flow; Material Deformation; Off-Label Use; Obstruction of Flow; Material Deformation
ON (B)(6) 2020, A 23 MM EPIC STENTED PORCINE AORTIC HEART VALVE WAS IMPLANTED IN THE PULMONARY POSITION. WHEN THE PATIENT CAME OFF OF BYPASS, PULMONARY STENOSIS WAS NOTED. THE PATIENT WAS PLACED BACK ON BYPASS AND THE VALVE WAS EXPLANTED AND REPLACED WITH ANOTHER EPIC STENTED PORCINE AORTIC HEART VALVE TO RESOLVE THE EVENT. WHILE INSPECTING THE EXPLANTED VALVE, A PINCHED CREASE AND SOME LEAFLET REDUNDANCY WITHIN IN THE VALVE LEAFLETS. THE PHYSICIAN ALLEGES THAT THE STENOSIS WAS CAUSED BY THE NATIVE LEAFLET OF THE PULMONARY VALVE AND WAS NOT CAUSED BY THE EPIC VALVE AND DID NOT FEEL THIS WAS A VALVE ISSUE. THERE WAS NO CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE AND THE PATIENT REMAINED HEMODYNAMICALLY STABLE THROUGHOUT. THE PATIENT IS RECOVERING AND DOING WELL.
Patient problems: Stenosis
MAUDE report 11015431 ↗
Other heart-valve, non-allograft tissue devices
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue2 deaths404 reports
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue385 reports
- PERCEVAL PVS23Corcym Canada Corp · heart-valve, non-allograft tissue26 deaths337 reports
- MOSAIC® 305C23Medtronic, Inc. · heart-valve, non-allograft tissue327 reports
- MOSAIC® 305C25Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths324 reports
- FREESTYLE® FR995-27Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths318 reports
- FREESTYLE® FR995-29Medtronic, Inc. · heart-valve, non-allograft tissue288 reports
- FREESTYLE® FR99525Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths280 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page