Swartz™ 407452Recalls & reported problems

St. Jude Medical, Inc. · BRAIDED TRANSSEPTAL GUIDING INTRODUCER · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 05414734205764), received between Feb 5, 2019 and Apr 2, 2026 — classified as 3 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fluid/Blood Leak2
  • Material Separation2
  • Adverse Event Without Identified Device or Use Problem1
  • Difficult to Insert1
  • Fracture1
  • Gas/Air Leak1
  • Material Puncture/Hole1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Cardiac Perforation1
  • Foreign Body Embolism1
  • Foreign Body In Patient1
  • Stroke/CVA1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 2, 2026Fluid/Blood Leak

    DURING THE PROCEDURE, THE SHEATH LEAKED. THE INTRODUCER WAS REPLACED AND THE PROCEDURE WAS COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24764086 ↗
  • MalfunctionMar 2, 2026Fluid/Blood Leak

    DURING A PULMONARY VEIN ISOLATION PROCEDURE, BLOOD LEAKED FROM THE HEMOSTASIS VALVE. THE SHEATH WAS EXCHANGED AND THE PROCEDURE WAS COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24492321 ↗
  • MalfunctionMar 2, 2026Gas/Air Leak

    DURING AN ATRIAL FIBRILLATION PROCEDURE, AFTER PERFORMING TRANSSEPTAL PUNCTURE WHILE FLUSHING, AIR BUBBLES WERE OBSERVED. THE SHEATH WAS REPLACED AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24485007 ↗
  • MalfunctionDec 16, 2025Material Puncture/Hole; Material Puncture/Hole

    DURING THE TRANSSEPTAL PUNCTURE, THE DILATOR AND THE SHEATH WERE PUNCTURED SEVERAL TIMES BY THE NEEDLE IN THE AREA OF THE CURVATURE. BOTH THE NEEDLE AND THE SHEATH WERE REPLACED. AN AGILIS SHEATH WAS USED WHICH RESOLVED THE ISSUE AND THE PROCEDURE WAS COMPLETED WITH NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23824632 ↗
  • InjuryJul 25, 2024Material Separation; Material Separation

    DURING THE ATRIAL FIBRILLATION PROCEDURE, PART OF THE SHEATH BROKE OFF FROM THE DEVICE REQUIRING SURGICAL INTERVENTION TO RETRIEVE IT. ALL PIECES WERE ACCOUNTED FOR WITH FLUOROSCOPY. THE PHYSICIAN CANCELLED THE PROCEDURE DUE TO THE ISSUE WITH THE SHEATH.

    Patient problems: Foreign Body In Patient

    MAUDE report 19825939 ↗
  • InjuryApr 29, 2021Fracture; Difficult to Insert; Material Separation; Fracture; Difficult to Insert; Material Separation

    DURING A VENTRICULAR TACHYCARDIA PROCEDURE, THE GRAY SOFT TIP OF THE SHEATH DETACHED IN PATIENT AND TWO DAYS LATER, THE PATIENT EXPERIENCED STROKE SYMPTOMS. AN MRI WAS CONDUCTED TO INITIALLY DIAGNOSE THE STROKE. DURING THE PROCEDURE, DIFFICULTY WAS NOTED WHEN INSERTING A NON-ABBOTT 8.5F CATHETER INTO THE INTRODUCER AFTER MAPPING AND ABLATION WAS CONDUCTED. ADDITIONALLY, THE 8.5F NON-ABBOTT CATHETER WAS DIFFICULT TO FULLY INSERT THROUGH THE SHEATH AND MANIPULATING THE CATHETER IN THE PATIENT FELT ABNORMAL. THE PHYSICIAN REMOVED THE SHEATH AND CATHETER TOGETHER FROM THE PATIENT AND UPON REMOVAL, THE GRAY SOFT TIP OF THE SHEATH WAS NOTED TO HAVE BEEN DETACHED. THE REMAINDER OF THE SHEATH TIP WAS SHEARED AND HANGING AT THE END OF THE SHEATH. NO INTERVENTION WAS ADMINISTERED AS THE GRAY SOFT TIP PIECES HAD APPEARED TO DISINTEGRATE IN THE PATIENT AND ALL PIECES WERE NOT ACCOUNTED FOR SINCE THEY COULD NOT BE VISUALIZED DUE TO BEING OPAQUE. TWO DAYS FOLLOWING THE PROCEDURE THE PATIENT EXPERIENCED STOKE SYMPTOMS OF BLURRED VISION OF THE LEFT EYE, HOWEVER NO INTERVENTION WAS NOTED TO HAVE BEEN CONDUCTED. FURTHER INFORMATION REGARDING PRE ANTICOAGULATION AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY A

    Patient problems: Foreign Body Embolism; Stroke/CVA

    MAUDE report 11749586 ↗
  • InjuryFeb 5, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    RELATED MANUFACTURING REF: 3008452825-2019-00041, 3008452825-2019-00042, 3008452825-2019-00043, 3008452825-2019-00044, 3005334138-2019-00050, 3005334138-2019-00051, 3008452825-2019-00045. FOLLOWING A PULMONARY VEIN ISOLATION PROCEDURE, A PERICARDIAL EFFUSION WAS NOTED VIA ECHOCARDIOGRAPHY. A PERICARDIOCENTESIS WAS PERFORMED TO STABILIZE THE PATIENT. NO PATIENT SYMPTOMS WERE NOTED THROUGHOUT THE PROCEDURE AND THERE WERE NO PERFORMANCE ISSUES WITH ANY ABBOTT DEVICE.

    Patient problems: Cardiac Perforation

    MAUDE report 8304822 ↗

Other INTRODUCER, CATHETER devices

All INTRODUCER, CATHETER devices →