Lamitrode Tripole™ 3219 (UDI 05415067017628)Recalls & reported problems
St. Jude Medical, Inc. · 16 Lead, 60 cm · Class 3 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 22
- Deaths reported
- 0
- Injuries reported
- 22
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 22 adverse event reports that list this exact device (DI 05415067017628), received between Dec 20, 2018 and Mar 11, 2026 — classified as 22 injuries.
The most frequently reported specific device problem is “High impedance” (8 reports).
14 other recalls cover devices cleared under the same FDA submission (P010032); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- High impedance8
- Therapeutic or Diagnostic Output Failure4
- Adverse Event Without Identified Device or Use Problem3
- Impedance Problem2
- Insufficient Device Problem Information2
- Low impedance1
- Material Fragmentation1
- Material Split, Cut or Torn1
Patient problems
- Inadequate Pain Relief12
- No Clinical Signs, Symptoms or Conditions5
- Insufficient Information2
- Therapeutic Effects, Unexpected1
- Undesired Nerve Stimulation1
- Unspecified Infection1
Recent adverse event reports
The 22 most recent of 22 reports, in the reporter's own words as published by the FDA.
InjuryMar 11, 2026High impedance
ADDITIONAL INFORMATION INDICATES SURGICAL INTERVENTION WAS UNDERTAKEN ON 01 APRIL 2026 WHEREIN LEAD WAS EXPLANTED AND REPLACED TO ADDRESS THE ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24570159 ↗InjuryFeb 19, 2026High impedance
IT WAS REPORTED THE PATIENT'S IPG WAS INOPERABLE AND UNABLE TO ENTER MRI MODE DUE TO HIGH IMPEDANCES. IN TURN, SURGICAL INTERVENTION WAS UNDERTAKEN WHEREIN THE LEAD AND IPG WERE EXPLANTED AND REPLACED. EFFECTIVE THERAPY WAS ESTABLISHED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24387359 ↗InjuryDec 12, 2025Therapeutic or Diagnostic Output Failure; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT THE PATIENT'S LEAD WAS EXPLANTED AN REPLACED FOR AN UNKNOWN REASON.
Patient problems: Inadequate Pain Relief
MAUDE report 23792707 ↗InjuryFeb 7, 2025High impedance; High impedance
DIAGNOSTICS REVEALED HIGH IMPEDANCE. AS A RESULT, SURGICAL INTERVENTION WAS UNDERTAKEN ON (B)(6) 2025 WHEREIN THE LEAD WAS EXPLANTED AND REPLACED TO ADDRESS THE ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21333915 ↗InjuryJan 9, 2024High impedance; Impedance Problem; High impedance; Impedance Problem
ADDITIONAL INFORMATION WAS RECEIVED STATING PRIOR TO THE SURGERY THE PATIENT HAD HIGH IMPEDANCES. ALSO, SURGICAL INTERVENTION TOOK PLACE WHERE THE LEAD WAS EXPLANTED AND REPLACED TO ADDRESS THE ISSUE. EFFECTIVE STIMULATION WAS RESTORED.
Patient problems: Inadequate Pain Relief
MAUDE report 18475943 ↗InjuryOct 6, 2023High impedance; High impedance
IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING IMPEDANCES ISSUES. SURGICAL INTERVENTION MAY TAKE PLACE AT A LATER DATE TO ADDRESS THE ISSUE.
Patient problems: Inadequate Pain Relief
MAUDE report 17885361 ↗InjurySep 25, 2023High impedance; High impedance
ADDITIONAL INFORMATION RECEIVED INDICATES THAT SURGICAL INTERVENTION TOOK PLACE WHERE THE PATIENTS LEAD WAS EXPLANTED AND REPLACED.
Patient problems: Inadequate Pain Relief
MAUDE report 17807812 ↗InjuryJul 5, 2023Therapeutic or Diagnostic Output Failure; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT PATIENT HAS BEEN GETTING NO THERAPY RELIEF. SURGICAL INTERVENTION MAY TAKE PLACE AT A LATER DATE TO ADDRESS THE ISSUE.
Patient problems: Inadequate Pain Relief
MAUDE report 17254941 ↗InjuryMay 30, 2023Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT THE PATIENT'S LEADS WERE EXPLANTED AFTER BEING CUT DURING A PRIOR SURGERY. THE LEAD WAS REPLACED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17022253 ↗InjuryMay 8, 2023High impedance; High impedance
IT WAS REPORTED THE PATIENT EXPERIENCED UNDESIRED NERVE STIMULATION WITH THEIR SCS SYSTEM. IN TURN, REPROGRAMMING WAS UNABLE TO RESOLVE THE ISSUE. AS A RESULT, SURGICAL INTERVENTION MAY BE PENDING TO ADDRESS THE ISSUE.
Patient problems: Undesired Nerve Stimulation
MAUDE report 16885102 ↗InjuryFeb 27, 2023Therapeutic or Diagnostic Output Failure; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT PATIENT EXPERIENCED INEFFECTIVE THERAPY. AS A RESULT, SURGICAL INTERVENTION WAS UNDERTAKEN ON 8 MAR 2023 WHEREIN NEW LEAD WAS IMPLANTED TO ADDRESS THE ISSUE. EFFECTIVE THERAPY WAS RESTORED POST OPERATIVELY.
Patient problems: Inadequate Pain Relief
MAUDE report 16449173 ↗InjuryJan 5, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED AN INFECTION WAS PRESENT AT THE LEAD INSERTION SITE. PATIENT WAS PRESCRIBED ORAL ANTIBIOTICS. PATIENT IS TO FOLLOW-UP WITH PHYSICIAN AS THE NEXT COURSE OF ACTION.
Patient problems: Unspecified Infection
MAUDE report 16108974 ↗InjuryJan 3, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
RELATED MANUFACTURER REFERENCE NUMBER: 1627487-2023-00047. IT WAS REPORTED THAT PATIENT UNDERWENT SURGICAL INTERVENTION AT UNKNOWN DATE FOR UNKNOWN REASON WHEREIN THE ENTIRE SYSTEM WAS EXPLANTED.
Patient problems: Insufficient Information
MAUDE report 16092002 ↗InjuryDec 23, 2022Material Split, Cut or Torn; Material Split, Cut or Torn
IT WAS REPORTED THAT THE PATIENT¿S LEAD WAS ACCIDENTALLY CUT DURING A PROCEDURE. IN TURN SURGICAL INTERVENTION MAY OCCUR TO ADDRESS THE ISSUE.
Patient problems: Inadequate Pain Relief
MAUDE report 16042520 ↗InjuryDec 7, 2022Use of Device Problem; Impedance Problem; Use of Device Problem; Impedance Problem
IT WAS REPORTED THAT THE PATIENT LEAD WAS ABANDONED AND LEFT IMPLANTED DURING A SYSTEM REVISION ON (B)(6) 2022. NO INTERVENTION IS PLANNED TO RETRIEVE THE LEAD.
Patient problems: Inadequate Pain Relief
MAUDE report 15937244 ↗InjuryNov 17, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
RELATED MANUFACTURER REPORT NUMBER: 1627487-2022-06261. IT WAS REPORTED THE PATIENT DID NOT RECHARGE THE IPG AS RECOMMENDED. AS SUCH, THE IPG BECAME INOPERABLE. IN TURN, THE PATIENT UNDERWENT SURGICAL INTERVENTION WHEREIN THE PATIENT'S IPG WAS EXPLANTED AND REPLACED. IT WAS REPORTED THE PATIENT'S LEAD WAS EXPLANTED AND REPLACED FOR AN UNKNOWN REASON.
Patient problems: Insufficient Information
MAUDE report 15819737 ↗InjuryOct 19, 2022Low impedance; Low impedance
RELATED MANUFACTURER REFERENCE NUMBER: 1627487-2022-04989. IT WAS REPORTED THE PATIENT HAD EFFECTIVE THERAPY, BUT LOW IMPEDANCES ON CONTACTS 8-15. AS A RESULT, THE LEAD WAS REPLACED SO THE PATIENT COULD UTILIZE MRI MODE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15635937 ↗InjuryJul 11, 2022High impedance; High impedance
IT WAS REPORTED THAT PATIENT EXPERIENCED INEFFECTIVE THERAPY. SYSTEM DIAGNOSTICS RECORDED HIGH IMPEDANCE ON ALL LEAD CONTACTS. AS A RESULT, SURGERY INTERVENTION WAS UNDERTAKEN WHEREIN THE LEAD WAS EXPLANTED AND REPLACED. EFFECTIVE THERAPY WAS RESTORED POST OPERATIVELY.
Patient problems: Inadequate Pain Relief
MAUDE report 14977444 ↗InjuryMar 29, 2022Therapeutic or Diagnostic Output Failure; Therapeutic or Diagnostic Output Failure
RELATED MANUFACTURER REFERENCE NUMBER: 3006705815-2022-01608. IT WAS REPORTED THE PATIENT EXPERIENCED INEFFECTIVE STIMULATION WITH THE IMPLANTED LEAD AND THE IPG HAD REACHED END OF LIFE. AS A RESULT, SURGICAL INTERVENTION WAS UNDERTAKEN WHEREIN THE IPG AND LEAD WERE EXPLANTED AND REPLACED TO ADDRESS THE ISSUE.
Patient problems: Inadequate Pain Relief
MAUDE report 13940938 ↗InjuryNov 12, 2020Migration; Migration
IT WAS REPORTED THAT PATIENT EXPERIENCED A FALL WHICH RESULTED TO LEAD MIGRATION. AS A RESULT THE SURGICAL INTERVENTION WAS UNDERTAKEN WHERE IN THE LEAD WAS EXPLANTED AND REPLACED ADDRESSING THE ISSUE.
Patient problems: Inadequate Pain Relief
MAUDE report 10827135 ↗InjuryJan 14, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE 2 OF 2: REFERENCE MFR. REPORT: 3006705815-2019-00210. IT WAS REPORTED THE PATIENT EXPERIENCED INADEQUATE RELIEF. AS A RESULT, THE SYSTEM WAS EXPLANTED.
Patient problems: Inadequate Pain Relief
MAUDE report 8246486 ↗InjuryDec 20, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DEVICE 1 OF 2: REFERENCE MFR. REPORT# 3006705815-2018-03418. IT WAS REPORTED THAT THE PATIENT WAS EXPERIENCING STIMULATION IN THE WRONG LOCATION. IN TURN, THE PATIENTS SYSTEM WAS EXPLANTED AND REPLACED. EFFECTIVE STIMULATION WAS CONFIRMED POST-OP.
Patient problems: Therapeutic Effects, Unexpected
MAUDE report 8185731 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P010032. One submission often covers many models, so check the product and lot details in each record.
- Z-0458-2026 · Oct 6, 2025 · Open, ClassifiedEterna SCS IPG (Implantable Pulse Generator), Model Number 32400
- Z-2511-2023 · Jul 18, 2023 · Open, ClassifiedInfinity 7 Implantable Pulse Generator REF 6662 Product Description: The implantable pulse generator (IPG) is an electronic device designed to be connected to one or more extensio
- Z-2507-2023 · Jul 18, 2023 · Open, ClassifiedProclaim Plus 5 Implantable Pulse Generator REF 3670 Product Description: The implantable pulse generator (IPG) is an electronic device designed to be connected to one or more ext
- Z-2510-2023 · Jul 18, 2023 · Open, ClassifiedInfinity 5 Implantable Pulse Generator REF 6660 Product Description: The implantable pulse generator (IPG) is an electronic device designed to be connected to one or more extensio
- Z-2508-2023 · Jul 18, 2023 · Open, ClassifiedProclaim Plus 7 Implantable Pulse Generator REF 3672 Product Description: The implantable pulse generator (IPG) is an electronic device designed to be connected to one or more ext
- Z-2505-2023 · Jul 18, 2023 · Open, ClassifiedProclaim XR 5 Implantable Pulse Genterator REF 3660 (previously known as Proclaim" 5 Elite IPG) Model 3660 Product Description: The implantable pulse generator (IPG) is an electr
- Z-2506-2023 · Jul 18, 2023 · Open, ClassifiedProclaim" XR 7 Implantable Pulse Generator REF 3662 (previously known as Proclaim" 7 Elite IPG) Product Description: The implantable pulse generator (IPG) is an electronic device
- Z-2509-2023 · Jul 18, 2023 · Open, ClassifiedProclaim DRG Implantable Pulse Generator REF 3664 Product Description: The implantable pulse generator (IPG) is an electronic device designed to be connected to one or more extens
- Z-2691-2017 · Jun 2, 2017 · TerminatedProclaim 5 Elite, implantable Pulse Generator, REF 3660, Rx only, STERILE EO Product Usage: The Proclaim implantable pulse generator (IPG) is an electronic device designed to be c
- Z-2692-2017 · Jun 2, 2017 · TerminatedProclaim 7 Elite, Implantable Pulse Generator, REF 3662, Rx only, STERILE EO Product Usage: The Proclaim implantable pulse generator (IPG) is an electronic device designed to be c
- Z-1785-2013 · Nov 30, 2012 · TerminatedEon and Eon Mini charging system, model numbers Eon -3701 (Wall Charger), 3711 (Portable Charger) and Eon Mini -3721 (Charger); This is a continuation of the firm's July 2012 reca
- Z-0025-2013 · Sep 4, 2012 · TerminatedThe Eon Mini Implantable Pulse Generator (IPG) is a 16-channel, rechargeable, multi-program system that allows the connection of one or two leads with four, eight, and 16 electrode
- Z-1738-2013 · Jul 26, 2012 · TerminatedEon - 3701 (Wall Charger) and 3711 (Portable Charger). Product Usage: Eon: Eon system is indicated as an aid in the management of chronic intractable pain of the trunk and/or li
- Z-3091-2011 · Jun 2, 2009 · TerminatedSoftware version 3.3 for Rapid Programmer devices, Model 3832. Software version 3.3 for Rapid Programmer devices, a personal digital assistant (PDA) based programmer supporting im
Other STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF devices
- Octrode™ 3186St. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF30 deaths32,096 reports
- Intellis™ AdaptiveStim® 97715Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF2 deaths23,976 reports
- RestoreSensor™SureScan® 97714Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF6 deaths17,903 reports
- Proclaim™ 3660St. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF2 recalls25 deaths13,336 reports
- Intellis™ AdaptiveStim® 97715Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF11,487 reports
- Precision Spectra ™ SC-1132Boston Scientific Neuromodulation Corporation · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF53 deaths11,269 reports
- Proclaim™ 5 EliteSt. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF1 recall10 deaths9,661 reports
- Proclaim™ 7 EliteSt. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF1 recall12 deaths7,299 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page