Skip to content

GN Hearing 21655100Recalls & reported problems

Gn Hearing A/S · EM,NC-HA-HPNG8 · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05708296213368), received between Mar 19, 2026 and Aug 27, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 27, 2026Detachment of Device or Device Component

    It was reported that the brass riffel that hold the cerustop filter, fell out of the new encase mold on a hearing aid. The riffel fell out when the hearing care professional was replacing the user's wax guard and was not in the ear of the user. The object did not require removal and no harm was reported. This is an initial report. Further information is expected.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50473170 ↗
  • MalfunctionMar 19, 2026Detachment of Device or Device Component

    ESTIMATED DATE OF INCIDENT 01 FEB 2026. IT HAS BEEN REPORTED THAT THE WAX GUARD OF A NCASED EARMOULD IS NOT STAYING IN PLACE AND HAS BROKEN OFF INTO CX EAR. IT HAS NOT BEEN POSSIBLE TO CONFIRM WHAT CX REFERS TO, BUT MOST LIKELY IT REFERS TO 'CUSTOMER'. NO SYMPTOMS HAVE BEEN REPORTED. INITIAL SCREENING QUESTIONS ASKING IF THERE WAS ANY HARM TO THE USER, OR ANY POTENTIAL FOR HARM FOLLOWING THE INCIDENT HAVE BOTH BEEN ANSWERED WITH "NO". FURTHER FOLLOW UP IS REQUESTED. 17APR 2026. NO FURTHER FOLLOW UP FROM THE REPORTER RECEIVED. 13MAY 2026. NO FURTHER FOLLOW UP FROM THE REPORTER HAS BEEN RECEIVED, OR IS EXPECTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24636609 ↗

Other Hearing aid, air conduction with wireless technology devices

All Hearing aid, air conduction with wireless technology devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page