Inion CompressOn™ Instrument 1 (REF IFS-2708)Recalls & reported problems
Inion Oy · Drill tap Ø 2.7 mm, cannulated · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 06438408008061), received between Nov 14, 2025 and Nov 14, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
- Material Split, Cut or Torn1
Patient problems
- Infiltration into Tissue1
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 14, 2025Fracture; Material Split, Cut or Torn; Fracture; Material Split, Cut or Torn
DURING A KNEE OCD FIXATION, AFTER THE INSERTION OF THE FIRST K-WIRE, INION DRILL TAP BROKE AT ITS TIP. THIS WAS NOTICED AFTER THE INSERTION OF THE SECOND K-WIRE, WHEN THE DRILL TAP BECAME MORE TIGHTLY STUCK. UPON TAKING THE DRILL TAP OUT, IT WAS DISCOVERED THAT THE K-WIRE HAD BROKEN INSIDE THE BONE. AT THIS POINT THE FIRST K-WIRE WAS ALSO CHECKED (SCREW WAS ALREADY INSERTED) AND IT WAS DISCOVERED THAT THE FIRST K-WIRE HAD ALSO BEEN BROKEN INSIDE THE BONE. THE BROKEN K-WIRE PIECES WERE REMOVED FROM POSTERIOR (POPLITEAL) SIDE, WHICH ADDED 60 MINUTES TO THE OPERATION TIME. A SMALL PIECE OF THE DRILL TAP TIP (APPROXIMATELY 1MM) WAS LEFT INSIDE THE FIRST SCREW TUNNEL. BASED ON SURGEON'S EVALUATION, THE ONLY HARM TO PATIENT CAUSED BY THE INCIDENT WAS AN ADDITIONAL SURGICAL SCAR TO POPLITEAL SIDE. THIS EVENT IS BEING REPORTED AS IT CAUSED APPROXIMATELY A 60-MINUTE DELAY TO OPERATION TIME AND THE REMOVAL OF THE BROKEN K-WIRE PIECES FROM THE POPLITEAL SIDE CAUSED A CHANGE IN THE ORIGINAL OPERATION PLAN AND RESULTED IN AN ADDITIONAL SURGICAL SCAR TO POPLITEAL AREA. ALSO THE INION DRILL TAP BROKE DURING OPERATION AND A SMALL PIECE FROM THE DRILL TAP TIP WAS LEFT INSIDE THE SCREW TUNNEL. NOTE:
Patient problems: Infiltration into Tissue; Insufficient Information
MAUDE report 23552040 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page