Servo-i Base Unit 6487800Recalls & reported problems

Maquet Critical Care AB · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Maquet Servo-i ventilator is a breathing machine used in medical facilities. Its 835 reports include 4 deaths and 18 injuries. Many describe the ventilator failing its pre-use self-tests, such as leakage or pressure checks, and some describe power errors; many report no patient involvement. Reports fell to 190 in the last 12 months, down from 313 in the 12 months before. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
832
Deaths reported
4
Injuries reported
16
Recalls naming it
0

Summary

The FDA's MAUDE database contains 832 adverse event reports that list this exact device (DI 07325710000823), received between Aug 16, 2022 and Sep 30, 2026 — classified as 4 deaths, 16 injuries, 812 malfunctions.

The most frequently reported specific device problem is “Failure of Device to Self-Test” (378 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 22 reportsDec 2023: 28 reportsJan 2024: 7 reportsFeb 2024: 9 reportsMar 2024: 14 reportsApr 2024: 16 reportsMay 2024: 16 reportsJun 2024: 21 reportsJul 2024: 19 reportsAug 2024: 17 reportsSep 2024: 22 reportsOct 2024: 48 reportsNov 2024: 35 reportsDec 2024: 28 reportsJan 2025: 34 reportsFeb 2025: 22 reportsMar 2025: 39 reportsApr 2025: 24 reportsMay 2025: 24 reportsJun 2025: 18 reportsJul 2025: 31 reportsAug 2025: 32 reportsSep 2025: 13 reportsOct 2025: 13 reportsNov 2025: 14 reportsDec 2025: 37 reportsJan 2026: 27 reportsFeb 2026: 35 reportsMar 2026: 15 reportsApr 2026: 23 reportsMay 2026: 14 reportsJun 2026: 16 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 6 reportsOct 2026: 0 reports20242025202648
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure of Device to Self-Test378
  • Output Problem342
  • Mechanical Problem56
  • Infusion or Flow Problem54
  • Contamination47
  • Fracture13
  • Power Problem10
  • Increase in Pressure9

Patient problems

  • No Clinical Signs, Symptoms or Conditions812
  • Low Oxygen Saturation12
  • Insufficient Information4
  • Bradycardia2
  • Hypercalcemia2
  • Hyperventilation2
  • Hypoventilation2

Recent adverse event reports

The 25 most recent of 832 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Failure of Device to Self-Test

    It was reported that the ventilator failed Internal leakage test during Pre-use Check. There was no patient involvement. Manufacturer's Ref. #: (b)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50945957 ↗
  • MalfunctionSep 29, 2026Failure of Device to Self-Test

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50932645 ↗
  • MalfunctionSep 28, 2026Mechanical Problem; Infusion or Flow Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50916750 ↗
  • MalfunctionSep 25, 2026Failure of Device to Self-Test

    It was reported that the ventilator failed Internal leakage test during Pre-use Check. There was no patient involvement. Manufacturer's Ref. #: (b)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50896059 ↗
  • MalfunctionSep 25, 2026Fracture

    It was reported that the ventilator's support arm was broken. There was no patient involvement. Manufacturer's Ref. #: (b)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50895629 ↗
  • MalfunctionSep 25, 2026Output Problem; Power Problem

    During the inspection of the ventilator it was discovered that a technical error code indicating power error was generated. Moreover, according to provided device's logs, technical error code indicating an open safety valve was also generated.There was no patient involvement. Manufacturer's Ref. #: (b)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50894836 ↗
  • MalfunctionJun 30, 2026Output Problem

    IT WAS REPORTED THAT THE VENTILATOR GENERATED TECHNICAL ERROR CODE INDICATING POWER ERROR. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25662592 ↗
  • MalfunctionJun 29, 2026Contamination /Decontamination Problem; Failure of Device to Self-Test

    IT WAS REPORTED THAT VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF#: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25649247 ↗
  • MalfunctionJun 25, 2026Contamination; Power Problem

    IT WAS REPORTED THAT THE VENTILATOR HAD POWER SUPPLY ISSUE. DURING THE INSPECTION OF THE VENTILATOR, LIQUID WAS OBSERVED ON THE AC/DC PRINTED CIRCUIT BOARD. THERE WAS NO PATIENT HARM. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25626878 ↗
  • MalfunctionJun 24, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED PRESSURE TRANSDUCER TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25606085 ↗
  • MalfunctionJun 22, 2026Mechanical Problem; Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25585898 ↗
  • MalfunctionJun 22, 2026Mechanical Problem; Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED PRESSURE TRANSDUCER TEST AND INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25585409 ↗
  • MalfunctionJun 19, 2026Failure of Device to Self-Test; Output Problem

    IT WAS REPORTED THAT THE VENTILATOR FAILED FLOW TRANSDUCER TEST AND SAFETY VALVE TEST DURING PRE-USE CHECK. MOREOVER, THE VENTILATOR GENERATED A TECHNICAL ERROR CODE INDICATING ERROR IN THE INTERNAL MEMORY. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25558136 ↗
  • MalfunctionJun 18, 2026Output Problem

    IT WAS REPORTED THAT THE VENTILATOR GENERATED A TECHNICAL ERROR CODE INDICATING AN OPEN SAFETY VALVE. THERE WAS NO PATIENT HARM. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25545979 ↗
  • MalfunctionJun 16, 2026Mechanical Problem; Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25517471 ↗
  • MalfunctionJun 16, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED PRESSURE TRANSDUCER TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25514141 ↗
  • MalfunctionJun 11, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25467915 ↗
  • MalfunctionJun 10, 2026Electrical /Electronic Property Problem

    DURING ON-SITE VISIT IT WAS DISCOVERED THAT CONTROL PRINTED CIRCUIT BOARD HAS BEEN DEFECTIVE. THERE WAS NO PATIENT HARM. MANUFACTURER'S REF#: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25453484 ↗
  • MalfunctionJun 2, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF.#: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25359399 ↗
  • MalfunctionJun 2, 2026Contamination /Decontamination Problem; Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PR-USE CHECK. FURTHERMORE, THE AIR GAS MODULE WAS CONTAMINATED WITH WATER. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURE'S REF.#: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25357474 ↗
  • MalfunctionJun 1, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25353987 ↗
  • MalfunctionJun 1, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT INTERNAL LEAKAGE AND SAFETY VALVE TESTS FAILED DURING PRE-USE CHECK. NO PATIENT INVOLVEMENTS. MANUFACTURER'S REFERENCE #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25346483 ↗
  • MalfunctionMay 27, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED INTERNAL LEAKAGE TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF.#: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25298120 ↗
  • MalfunctionMay 26, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED SEVERAL TESTS DURING THE PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25277121 ↗
  • MalfunctionMay 24, 2026Failure of Device to Self-Test

    IT WAS REPORTED THAT THE VENTILATOR FAILED GAS SUPPLY TEST DURING PRE-USE CHECK. THERE WAS NO PATIENT INVOLVEMENT. MANUFACTURER'S REF. #: (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25266736 ↗

Other Ventilator, Continuous, Facility Use devices

All Ventilator, Continuous, Facility Use devices →