FREE GLIDING SCFE SCREW SYSTEM SCF-GWR320-CoCrRecalls & reported problems
Orthopediatrics Canada ULC · SCFE GUIDE WIRE CoCr Ø2.0mm x 330mm · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07540194008206), received between Feb 17, 2022 and Feb 17, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Improper or Incorrect Procedure or Method1
- Material Fragmentation1
Patient problems
- Device Embedded In Tissue or Plaque1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 17, 2022Material Fragmentation; Improper or Incorrect Procedure or Method; Material Fragmentation; Improper or Incorrect Procedure or Method
DURING A BILATERAL INSERTION OF THE SLIDING SCFE SCREW, IT WAS NOTED AFTER REMOVING THE 2.0MM GUIDE WIRE THAT THE TIP OF THE THREADED PORTION WAS LEFT IN THE PATIENT DURING THE SECOND HIP. IT WAS NOT DEEMED TO BE IN THE WAY OF THE SCREW, AND THE SURGEON HAS DECIDED NOT TO REMOVE IT. BOTH SCREWS WERE INSERTED, AND THE OUTCOME OF THE SURGERY WAS GOOD AND AS PLANNED. THE TIP OF THE WIRE IS OUTSIDE OF THE SCREW, AS THE DISTRIBUTOR UNDERSTOOD. THE HOSPITAL HAS RAISED THIS AS A FOREIGN BODY LEFT-IN-PATIENT INCIDENT. THE WIRE THAT BROKE HAD BEEN USED IN THE FIRST HIP AND WAS BEING USED BECAUSE THE OTHER WIRES (4 X SUPPLIED 2.0MM) WERE ALREADY BENT DURING THE SURGERY. SO, IT HAD ALREADY BEEN USED TO INSERT THE FIRST SCREW.
Patient problems: Device Embedded In Tissue or Plaque; No Clinical Signs, Symptoms or Conditions
MAUDE report 13548818 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page