Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07611996112528), received between Oct 26, 2020 and Dec 3, 2024 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Fracture” (6 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture6
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 3, 2024Break; Break
IT WAS REPORTED, THAT, DURING A THR SURGERY. A POLARCUP TRIAL INSERT NAV 22/57 BROKE, DURING REDUCTION. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING A S+N BACK-UP DEVICE. NO INJURY WAS REPORTED, AS A CONSEQUENCE OF THIS ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20833260 ↗MalfunctionAug 21, 2024Fracture; Fracture
IT WAS REPORTED THAT DURING A THR, THE POLARCUP TRIAL INSERT 57/22 BROKE. IT IS UNKNOWN IF ANY PIECE FELL INSIDE THE PATIENT. SURGERY WAS *PERFORMED, WITHOUT ANY DELAY, WITH THE SAME DEVICE. NO PATIENT COMPLICATIONS WERE REP%ORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20017091 ↗MalfunctionFeb 16, 2024Fracture; Fracture
IT WAS REPORTED THAT, DURING THR SURGERY, THE POLARCUP TRIAL INSERT NAV 22/57 WAS BROKEN. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING THE SAME DEVICE. NO INJURY WAS REPORTED AS A CONSEQUENCE OF THIS ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18727229 ↗MalfunctionDec 21, 2023Fracture; Fracture
IT WAS REPORTED THAT, DURING A THR SURGERY, A PIECE OF AN UNKNOWN TRIAL INSERT BROKE OFF DURING REDUCTION. THE BROKEN PIECE WAS RETRIEVED. NO DELAY WAS REPORTED, BUT IT IS UNKNOWN HOW THE PROCEDURE WAS COMPLETED. NO INJURIES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18378227 ↗MalfunctionMar 15, 2023Fracture; Fracture
IT WAS REPORTED THAT, ONE (1) OF THE FINS ON POLARCUP TRIAL INSERT NAV 22/57, BROKE OFF. THE PROCEDURE WAS RESUMED, WITHOUT ANY DELAY, USING A S+N BACK-UP DEVICE. PATIENT WAS NOT INJURED AS CONSEQUENCE OF THIS PROBLEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16547109 ↗MalfunctionJun 12, 2022Fracture; Fracture
IT WAS REPORTED THAT, A POLARCUP TRIAL INSERT NAV 22/57 IS BROKEN. IT IS UNKNOWN AT WHAT STAGE OF THE SURGERY THE INCIDENT OCCURRED. HOWEVER, IT IS KNOWN THAT A SN BACK-UP DEVICE WAS AVAILABLE AND THAT THERE WAS NO DELAY IN SURGERY. NO HARM TO THE PATIENT OR FURTHER COMPLICATIONS REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14672546 ↗MalfunctionOct 26, 2020Fracture; Fracture
IT WAS REPORTED THAT THE POLARCUP TRIAL INSERT NAV 22/57 BROKE IN SEVERAL PIECES. IT IS NOT KNOWN IF IT WAS INSIDE OF THE PATIENT. PROCEDURE WAS FINISHED WITH AN S+N BACKUP DEVICE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10737961 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page