OMEGA 704002Recalls & reported problems
Stryker GmbH · One-Step Insertion Wrench · Class 1
All models of OMEGA (20)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613153054412), received between Aug 20, 2015 and Jul 23, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
- Retraction Problem1
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 23, 2018Break; Retraction Problem
IT WAS REPORTED THAT DURING INSERTION OF THE LAG-SCREW USING THE ONE-STEP TECHNIQUE, AND PRIOR TO FULLY SEATING THE LAG SCREW, THE CONNECTING BOLT SHEARED OFF. DURING CONTINUED ATTEMPTS TO FULLY SEAT THE SCREW, THE LAG SCREW INTERLOCKING TABS SHEARED OFF. SUBSEQUENT ATTEMPTS TO FULLY SEAT OR REMOVE THE LAG SCREW WERE DIFFICULT. IT WAS REPORTED THAT ADDITIONAL OPERATIVE TIME WAS 30 MINUTES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7712317 ↗MalfunctionAug 20, 2015Break
THE CUSTOMER REPORTED THAT WHEN THE LAG SCREW WAS BEING INSERTED THE LAG SCREW SNAPPED OFF THE INSERTER. THE CUSTOMER REPORTED THAT THEY WERE USING THE ONE STEP INSERTION APPROACH AND THAT THE BONE WAS VERY HARD. THE CONSULTANT THOUGHT WITH HINDSIGHT THAT THEY SHOULD HAVE TAPPED BECAUSE OF THE HARDNESS OF THE BONE. AFTER THE SCREW SNAPPED A PIECE REMAINED IN THE PATIENT AND THIS WAS REMOVED USING A REDUCTION INSTRUMENT. ANOTHER SCREW WAS AVAILABLE TO COMPLETE THE CASE. THERE WAS A SURGICAL DELAY OF APPROXIMATELY 20 MINUTES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5019188 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page