VariAx 54-25375Recalls & reported problems

Stryker GmbH · VOLAR SMARTLOCK DR PL.NARROW,LEFT,LONG · Class 2 · Implant

All models of VARIAX (345)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613154345472), received between Sep 25, 2025 and Sep 25, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Difficult to Setup or Prepare1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 25, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare

    AS REPORTED: "IT WAS REPORTED THAT THE LOCKING SCREW WOULD NOT LOCK FIRMLY INTO THE LOCKING HOLE, AND THE SCREW WOULD JUST SPIN BOTH CLOCKWISE AND COUNTERCLOCKWISE. THE SURGEON COULDN'T REMOVE THE SCREW AND WITH ONLY ONE OTHER GOOD SCREW IN THE PROXIMAL SHAFT OF THE PLATE ABOVE HIS OSTEOTOMY, THE SURGEON HAD TO REDO THE CONSTRUCT WITH A LONGER PLATE. UPON PUTTING ON THE NEW PLATE (SAME VERSION OF PLATE BUT LONGER), THE SURGEON HAD THE SAME SCENARIO. UPON PUTTING ON THE PLATE USING THE IDENTICAL DRILL HOLES IN THE DISTAL END OF PLATE HAD HIS 3RD SCREW IN THE RADIAL STYLOID HOLE SPIN IN BOTH DIRECTIONS. THE LOCKING SCREW SPUN AGAIN AND COULDN'T BE REVERSED OUT OF THE PLATE. AT THIS POINT, THE SURGEON WAS REPORTEDLY FRUSTRATED AND HAD TO REMOVE THE PLATE AND SCREWS AND DECIDED TO CHANGE CONSTRUCTS USING ANOTHER VENDOR'S PLATE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY USING A DIFFERENT DEVICE.".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23144775 ↗