ANCHORAGE PLSL3018Recalls & reported problems
Stryker GmbH · Locking Screw · Class 2 · Implant
All models of ANCHORAGE (52)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613252262176), received between Jan 14, 2019 and Jan 14, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fitting Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fitting Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 14, 2019Fitting Problem
IT WAS REPORTED THAT THE SURGEON MADE A LISFRANC OPERATION WITH THE ANCHORAGE FOOT PLATING SYSTEM. THE PLATE WAS ALREADY IMPLEMENTED IN THE PATIENT WITH THREE LOCKING SCREWS AND ONE CORTICAL SCREW. THE LAST LOCK SCREW "CORKED" THROUGH THE LOCKING HOLE SO THAT IT NO LONGER LOCKED ONTO THE PLATE. SURGEON DECIDED TO REMOVE THE PLATE AND ALL THE SCREWS AND REPLACE THEM WITH NEW ONES. THE NEW PLATE AND SCREWS WORKED FINE. SURGICAL DELAY APPROX. 10 MINUTES. PLATE AND SCREWS WERE REMOVED AND REPLACED WITH NEW ONES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8246189 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page