ANCHORAGE XTV008001Recalls & reported problems
Stryker GmbH · Screwdriver bit, T8, AO quick coupling · Class 1
All models of ANCHORAGE (52)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613252266952), received between Sep 23, 2020 and Sep 23, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fracture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 23, 2020Fracture; Fracture
AS REPORTED: "USING MMI ANCHORAGE MTP CP PLATE, WHILE USING THE DISTAL LOCKING GUIDE A 2.0MM DRILL BIT TIP BROKE OFF IN THE PATIENT AND WE WERE UNABLE TO RECOVER IT. ALONG WITH THE DRILL BIT WHILE SCREWING IN THE LAST 3.5MM LOCKING SCREW THE T8 SCREWDRIVER TIP BROKE OFF IN THE SCREW HEAD UNABLE TO GET LOOSE AND OUT OF THE SCREW HEAD. BOTH DRILL BIT AND SCREWDRIVER HEAD STUCK IN THE SCREW WERE LEFT IN THE PATIENT AND SURGICAL SITE CLOSED." NO DELAY¿S OR MAJOR DISTRACTION TO THE CASE.
Patient problems: Foreign Body In Patient
MAUDE report 10573141 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page