VariAx 54-25683Recalls & reported problems
Stryker GmbH · VOLAR DR PLATE INTERM. RIGHT EXTRASHORT · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613252614500), received between Aug 25, 2021 and Aug 25, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Positioning Failure” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Positioning Failure1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 25, 2021Positioning Failure; Positioning Failure
AS REPORTED: "THE SURGEONS WERE PERFORMING AN OPEN REDUCTION PROCEDURE OF THE RIGHT DISTAL RADIO WHICH THE DORSAL PART WAS SOMETHING COMMINUTE, A RIGHT EXTRACTOR PLATE IS PLACED. DISTAL RADIO 49MM REFERENCE 5425683 LOT 1000428950 THE OVAL HOLE OF THE BRANCH IS FIXED TO THE DISTAL PART OF THE PLATE WITH A CORTICAL SCREW OF 2.7X 16MM VERIFYING WITH X-RAYS AND THEN FIXING THE DISTAL PART USING THE 2.0MM LOCKING GUIDE HOLES WHICH DO NOT BLOCK, SEVERAL DRILLINGS ARE MADE IN DIFFERENT HOLES BUT THE SAME HAPPENED WITHOUT BLOCKING THE SCREWS, WHICH HAD BEEN USED 2.4MM X 18MM, 20MM, 22MM BLOCK T. AND THEN THE LAST BRANCH OF THE DISTAL HOLE IS FIXED PROXIMAL PART OF THE PLATE WITH A 2.7X14MM CORTICAL SCREWS, IT IS DECIDED TO REMOVE THE PLATE TO VERIFY THE DIRECTION OF THE HOLES AND THEIR LOCKING FUNCTION, SMART LOOK SYSTEM, BUT THEY DO NOT BLOCK THE ORIFICES AND THEY ARE MADE WITH A NEW SCREWS. THE SURGEON WAS ANGRY BY SUCH EVENT WHICH DECIDES NOT TO USE THE DISTAL RADIO SYSTEM WITH THE USED PLATE ANY MORE AND TO FIX THE H, DISTAL RADIO OF L APTE WITH KIRSCHNER NAILS 1.25 AND 1.1MM."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12365698 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-PLF40Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page