VariAx 656418Recalls & reported problems
Stryker GmbH · Bone Screw, Fully Threaded, T8 · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 11
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 07613327068955), received between Mar 27, 2019 and Jun 30, 2023 — classified as 5 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem4
- Break3
- Fracture3
- Positioning Failure2
Patient problems
- Injury4
- No Known Impact Or Consequence To Patient4
- Reaction4
- No Clinical Signs, Symptoms or Conditions2
- Device Embedded In Tissue or Plaque1
- Failure of Implant1
- Foreign Body In Patient1
- Nonunion/Delayed-union Bone Fracture1
Recent adverse event reports
The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 30, 2023Break; Fracture; Break; Fracture
AS REPORTED : "SCREW HEAD BROKEN. OBVIOUS DEFECT. MATERIAL CONSEQUENCES: TIME LOST + MATERIAL LOST. FOR THE PATIENT: REAL LEVEL OF SERIOUSNESS." ADDITIONAL INFORMATION: "A SCREW BROKE WHEN TIGHTENED WITH THE SCREWDRIVER SUPPLIED WITH THE SCREWS. THE THREADED PART REMAINED IN THE PATIENT'S BONE, AND AN ADDITIONAL SCREW WAS POSITIONED IN AN ADJACENT HOLE IN THE PLATE."
Patient problems: Foreign Body In Patient
MAUDE report 17236373 ↗InjuryOct 9, 2020Fracture; Fracture
AS REPORTED: "ORIGINAL CASE WAS FOR A BUNION DEFORMITY, WHERE A LAPIDUS PROCEDURE WAS PERFORMED (B)(6) 2019. DISSECTION, JOINT PREPARATION, AND FIXATION DURING THE CASE WENT FLAWLESS. NO CONCERNS ON DAY OF THE CASE. THE PATIENT PRESENTED 4-6 WEEKS OUT WITH POSSIBLE NON UNION. UPON THE NEXT XRAYS TAKEN, A NON UNION WAS SHOWN, AND A FEW SCREWS USED THROUGH THE PLATE WERE BROKEN FROM THE MOVEMENTS AND INSTABILITY CAUSED BY THE NON UNION AT THE FUSION SITE." DATE OF EXPLANT REPORTED: (B)(6) 2020.
Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture
MAUDE report 10657722 ↗MalfunctionAug 11, 2020Fracture; Fracture
AS REPORTED: "SCREW HEAD BROKE OFF."
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10393855 ↗MalfunctionJul 15, 2020Positioning Failure; Positioning Failure
THE "VARIAX 2 LOCKING SCREWS T10 2.7" DID NOT LOCK INTO THE PLATE. NEW SCREWS WERE USED TO COMPLETE THE SURGERY SUCCESSFULLY. SURGICAL DELAY OF 15MIN. NOT LONGER.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10277943 ↗MalfunctionJul 15, 2020Positioning Failure; Positioning Failure
THE "VARIAX 2 LOCKING SCREWS T10 2.7" DID NOT LOCK INTO THE PLATE. NEW SCREWS WERE USED TO COMPLETE THE SURGERY SUCCESSFULLY. SURGICAL DELAY OF 15MIN. NOT LONGER.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10277934 ↗InjuryJan 3, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
OPEN REDUCTION AND INTERNAL FIXATION OF THE LEFT MIDFOOT. METALOSIS WAS OBSERVED DURING REMOVAL.
Patient problems: Injury; Reaction
MAUDE report 9549315 ↗InjuryJan 3, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
OPEN REDUCTION AND INTERNAL FIXATION OF THE LEFT MIDFOOT. METALLOSIS WAS OBSERVED DURING REMOVAL.
Patient problems: Injury; Reaction
MAUDE report 9549222 ↗InjuryJan 3, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RIGHT MIDFOOT OPEN REDUCTION + INTERNAL FIXATION + LISFRANC STABILISATION. METALLOSIS WAS OBSERVED DURING REMOVAL.
Patient problems: Injury; Reaction
MAUDE report 9549212 ↗InjuryJan 3, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
VARIAX FOOT PLATE METALOSIS NOTICED UPON REMOVAL ON (B)(6) 2019 BY SURGEON. IMPLANTED ON 5(B)(6) 2019. REMOVAL NOT FOR NON-UNION, JUST REMOVAL OF METALWARE.
Patient problems: Injury; Reaction
MAUDE report 9549103 ↗MalfunctionJul 29, 2019Break
CUSTOMER REPORTED THAT : "WRIST OSTEOSYNTHESIS BY PLATE AND SCREWS (VARIAX - STRYKER). SCREW HEAD BROKEN ON THE SCREWDRIVER BIT PROVIDED FOR THIS PURPOSE, ONCE THE SCREW HAS BEEN FULLY INSERTED. SCREW DRIVER BIT NO LONGER USABLE, SCREWDRIVER CHANGE. IF THE NECESSARY MATERIAL IS REMOVED, THE SCREW WILL BE DIFFICULT OR IMPOSSIBLE TO REMOVE, MAKING IT DIFFICULT TO REMOVE THE PLATE." BROKEN SCREWDRIVER WAS REPORTED UNDER (B)(4).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8839582 ↗MalfunctionMar 27, 2019Break
IT WAS REPORTED THAT, DURING A PRIMARY PROCEDURE ON A LEFT DISTAL RADIUS, WHEN SEATING THE NON-LOCKING SCREW, THE HEAD BROKE OFF JUST AS IT WAS FULLY SEATING. THE SCREW SHAFT WAS LEFT IN THE PATIENT AND SURGERY WAS COMPLETED SUCCESSFULLY WITH A SURGICAL DELAY OF LESS THAN ONE MINUTE. NO ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 8457928 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page