VariAx 657014Recalls & reported problems
Stryker GmbH · Locking Screw, Fully Threaded, T10 · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327069266), received between Dec 19, 2023 and Dec 19, 2023 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Deformity/ Disfigurement1
- Implant Pain1
- Loss of Range of Motion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryDec 19, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD SURGERY ON (B)(6) 2018 TO INSERT A CLAVICLE PLATE AND SCREWS. PATIENT WENT BACK 2-DAYS POST-OP BECAUSE HE WAS EXPERIENCING A LOT OF PAIN. RECEIVED A CALL FROM ANESTHESIOLOGIST TO FOLLOW UP, PATIENT MENTIONED PAIN IN HIS JAW AND EAR. MAINTAINS THAT THERE MIGHT HAVE BEEN DAMAGE TO HIS THROAT WHEN REMOVING THE INTUBATION TUBE. WENT TO SEE ORTHOPEDIC DOCTOR FOR FOLLOW UP A WEEK LATER FOR SUTURE REMOVAL AND WHEN BANDAGES WERE REMOVED IT WAS NOTICED THAT IT DID NOT LOOK NORMAL. PATIENT HAD HARDWARE AND 9 SCREWS INSERTED AND NOW HAS A BUMP STICKING OUT IN HIS CLAVICLE AND HAS BEEN HAVING PROBLEM EVER SINCE. HE IS EXPERIENCING PAIN AND LIMITED RANGE OF MOTION. CANNOT REALLY USE HIS LEFT ARM AND IS EXPERIENCING HIP PAIN. WHEN IN HOT WEATHER HE NEEDS TO COVER UP THE IMPLANT BECAUSE IT GETS HOT AND IT HURTS WHEN THE WEATHER IS COLD. HE CLAIMS THAT THE SURGERY IS BOTCHED. HARDWARE HAS NOT BEEN REMOVED AT THIS MOMENT.
Patient problems: Deformity/ Disfigurement; Implant Pain; Loss of Range of Motion
MAUDE report 18357110 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page