Stryker GmbH · Drill Bit, AO Dia2.0mm x 135mm, Scaled · Class 1
All models of VARIAX (345)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07613327069853), received between Jun 15, 2018 and Jun 11, 2025 — classified as 2 injuries, 5 malfunctions.
The most frequently reported specific device problem is “Break” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break7
- Fracture5
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Foreign Body In Patient4
- Insufficient Information2
- Device Embedded In Tissue or Plaque1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 11, 2025Break; Fracture; Break; Fracture
AS REPORTED: "ITEM 703690 BROKEN AND LEFT IN PATIENT'S BODY DURING SURGERY, NOT RETRIEVED IN THE SURGERY".
Patient problems: Foreign Body In Patient
MAUDE report 22183326 ↗InjuryDec 3, 2024Break; Fracture; Break; Fracture
AS REPORTED: "'THE TIP OF THE DRILL BIT BREAKS OFF DURING THE DRILLING PROCESS. THE TIP CANNOT BE RETRIEVED AND REMAINS IN THERE. IT CANNOT BE RULED OUT THAT THIS COULD LEAD TO HARM TO THE PATIENT IN THE FUTURE.''
Patient problems: Foreign Body In Patient
MAUDE report 20836495 ↗InjuryOct 18, 2024Break; Fracture; Adverse Event Without Identified Device or Use Problem; Break; Fracture; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY THE CUSTOMER THAT "A MEDICAL DEVICE INCIDENT (MDI) WITH HARM HAS BEEN REPORTED." UPDATE OCT (B)(6) AS PER HEALTH CANADA: "DRILL BIT BROKE OFF IN PATIENT'S ARM DURING SURGERY." UPDATE DEC (B)(6): THE PIECE REMAINS IN THE PATIENT AS IT WAS IN A PLACE THAT WOULD HAVE BEEN DIFFICULT TO GET TO; NO ATTEMPTS WERE MADE TO REMOVE.
Patient problems: Foreign Body In Patient; Insufficient Information
MAUDE report 20484506 ↗MalfunctionJan 25, 2023Break; Fracture; Break; Fracture
CUSTOMER CONTACTED US FOR A WICK THAT HAS BEEN BROKEN. IT IS UNKNOWN IF DEBRIS WAS LEFT IN THE PATIENT.
Patient problems: Insufficient Information
MAUDE report 16240002 ↗MalfunctionJul 19, 2022Break; Fracture; Break; Fracture
AS REPORTED: "THE DRILL REF 703690 BROKE DURING MEDICAL PROCEDURE. THE PART WAS LEFT INTO PATIENT BODY. PATIENT RETURNED TO HOSPITAL REQUESTING THE POSSIBILITY TO UNDERGO MRI WITH THE DRILL INSIDE A BODY."
Patient problems: Foreign Body In Patient
MAUDE report 15059949 ↗MalfunctionJun 15, 2018Break
IT WAS REPORTED BY THE DISTRIBUTOR THAT SURGEON PERFORM DRILLING WITH 2.0 DRILL BIT AND IT WAS BROKEN. SURGEON ASKED FOR THE SAME SAID DRILL BIT AND PERFORMED SECOND DRILLING, AND IT WAS BROKEN AGAIN. X-RAY SHOWED THE DRILL BITS WERE BROKEN IN THE BONE AND DRILL BITS WERE NOT REMOVED.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 7606385 ↗MalfunctionJun 15, 2018Break
IT WAS REPORTED BY THE DISTRIBUTOR THAT SURGEON PERFORM DRILLING WITH 2.0 DRILL BIT AND IT WAS BROKEN. SURGEON ASKED FOR THE SAME SAID DRILL BIT AND PERFORMED SECOND DRILLING, AND IT WAS BROKEN AGAIN. X-RAY SHOWED THE DRILL BITS WERE BROKEN IN THE BONE AND DRILL BITS WERE NOT REMOVED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7606384 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page