Skip to content

ASNIS 325032SRecalls & reported problems

Stryker GmbH · Cannulated Screw · Class 2 · Implant

All models of ASNIS (51)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327076042), received between Mar 26, 2024 and May 2, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation2
  • Material Deformation1
  • Material Twisted/Bent1
  • Unraveled Material1

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 2, 2024Material Fragmentation; Material Fragmentation

    AS REPORTED: "THREAD OF THE ASNIS 4.0X32MM SCREW IS LOOSENING. IN ORDER TO COMPLETE THE SURGERY THE SCREW WAS REMOVED AND NEW SCREW WAS PLACED."

    Patient problems: Insufficient Information

    MAUDE report 19235316 ↗
  • MalfunctionMar 26, 2024Material Fragmentation; Unraveled Material; Material Deformation; Material Twisted/Bent; Material Fragmentation; Unraveled Material; Material Deformation; Material Twisted/Bent

    AS REPORTED: "ON 29.02.2024 AN ASNIS SCREW OF WHICH THE THREAD CAME LOOSE. HE WAS TWISTED INTO A METATARSAL. ANOTHER K-WIRE CROSSED BUT WE DOUBT IF IT WAS IN THE WAY." 26-MAR-2024 - UPDATE. PATIENT INVOLVEMENT?: YES, BUT NO PERMANENT INJURY. PATIENT ADVERSE CONSEQUENCES?: WE WERE ABLE TO REMOVE THE SCREW WAS THE PROCEDURE COMPLETED SUCCESSFULLY?: WE WERE ABLE TO REMOVE THE SCREW IN ITS ENTIRETY AND INSTALL A NEW ONE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18981335 ↗