ASNIS 325046SRecalls & reported problems
Stryker GmbH · Cannulated Screw · Class 2 · Implant
All models of ASNIS (51)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327076196), received between Jun 17, 2020 and Jun 20, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture2
- Break1
- Material Fragmentation1
Patient problems
- Device Embedded In Tissue or Plaque1
- Foreign Body In Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 20, 2023Break; Fracture; Material Fragmentation; Break; Fracture; Material Fragmentation
IT WAS REPORTED THAT DURING REMOVAL OF THE SCREW, THE MATERIAL GRADUALLY PROGRESSIVELY TWISTED AND THEN DISINTEGRATED IN THE PATIENT PREVENTING THE COMPLETE REMOVAL OF THE DEVICE. THE DOCTOR BROKE THE SCREW AS CLOSE TO THE BONE AS POSSIBLE AND IT IS DISTAL ENOUGH NOT TO INTERFERE WITH A FUTURE TOTAL KNEE REPLACEMENT. THIS RESULTED IN A 30 MINUTE SURGICAL DELAY AND THERE WILL BE NO NEED TO SCHEDULE ANOTHER SURGERY.
Patient problems: Foreign Body In Patient
MAUDE report 17161252 ↗MalfunctionJun 17, 2020Fracture; Fracture
PRIMARY PROCEDURE, ELBOW FRACTURE. IT WAS REPORTED THAT WHEN MANUALLY IMPLANTING THE 4.0 CANNULATED SCREW, THE SURGEON FELT THE SCREW SNAP WHEN IT WAS APPROXIMATELY HALFWAY IMPLANTED. INTRA-OPERATIVE IMAGING SHOWED THAT THE PORTION IN THE PATIENT'S BONE WAS SHATTERED. THE SURGEON REMOVED AS MANY OF THE PIECES AS HE COULD. ONE SMALL PIECE REMAINED IN THE PATIENT AND IS TRAPPED IN WITH THE SECOND IMPLANTED CANNULATED SCREW. SURGERY WAS COMPLETED SUCCESSFULLY WITH A DELAY OF APPROXIMATELY 45 MINUTES.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 10161992 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page