VARIAX 657310SRecalls & reported problems
Stryker GmbH · Locking Screw · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 10
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 07613327086799), received between Jul 22, 2020 and Feb 19, 2025 — classified as 10 malfunctions.
The most frequently reported specific device problem is “Positioning Failure” (10 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Positioning Failure10
- Material Fragmentation2
Patient problems
- No Clinical Signs, Symptoms or Conditions10
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 19, 2025Positioning Failure; Positioning Failure
AS REPORTED: "THE LOCKING SCREW ON THE VARIAX FIBULA PLATE FAILED TO LOCK. AFTER OPENING ANOTHER SCREW, THE SURGERY WAS COMPLETED WITHOUT ANY PROBLEMS".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21417486 ↗MalfunctionJul 17, 2024Positioning Failure; Positioning Failure
AS REPORTED: "LOCKING SCREW DID NOT LOCK." 7/4/2024 - ADDITIONAL INFORMATION RECEIVED. 3 SCREWS WERE SUCCESSFULLY IMPLANTED. LOCKING BAD SCREW IS NOT PUT IN, AND IT IS FINISHED AS IT IS. THE SURGEON IS RELATIVELY SATISFIED (BECAUSE IT IS USED IN CONJUNCTION WITH A TENSION BAND).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19767452 ↗MalfunctionMar 21, 2023Positioning Failure; Material Fragmentation; Positioning Failure; Material Fragmentation
IT WAS REPORTED: "THE LOCKING SCREW DID NOT LOCK TO THE PLATE. A THIN METAL PIECE WAS FOUND DURING THE SCREW INSERTION. THE SCREW WAS REPLACED AND THE NEW SCREW WAS ABLE TO LOCK TO THE PLATE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16587936 ↗MalfunctionMar 20, 2023Positioning Failure; Positioning Failure
AS REPORTED: "THE LOCKING SCREW DID NOT LOCK TO THE PLATE. THE SCREW AND THE PLATE WERE REPLACED".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16577564 ↗MalfunctionNov 16, 2022Positioning Failure; Positioning Failure
AS REPORTED: "THE LOCKING SCREW DID NOT LOCK TO THE PLATE AFTER DRILLING WITH 2.6MM DRILL. ANOTHER LOT NUMBER SCREW WITH THE SAME SIZE LOCKED AGAINST THE SAME HOLE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15804089 ↗MalfunctionJun 28, 2022Positioning Failure; Positioning Failure
AS REPORTED: "THE LOCKING SCREW DID NOT LOCK TO THE PLATE. SPARE SCREW WAS ABLE TO LOCK."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14840540 ↗MalfunctionJan 17, 2022Positioning Failure; Positioning Failure
AS REPORTED: "THE SUBJECT SCREW DID NOT LOCK TO THE FIBULA PLATE. THE SURGEON EXCHANGED IT TO A NEW ONE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13266548 ↗MalfunctionJan 4, 2022Positioning Failure; Positioning Failure
IT WAS REPORTED THAT INTRAOPERATIVELY, THE LOCKING DID NOT LOCK, SO IT WAS REPLACED WITH A NEW SCREW.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13158084 ↗MalfunctionFeb 24, 2021Positioning Failure; Positioning Failure
IT WAS REPORTED: "DURING THE INITIAL ORIF PROCEDURE FOR FIBULA (RIGHT SIDE), WHEN THE SURGEON ATTEMPTED TO INSERT THE 10MM LOCKING SCREW, IT DIDN'T FEEL LIKE IT WAS SPINNING OR TIGHTENING. THE REPORTING SR CONFIRMED THAT ANGLE OF THE DRILLING WAS LESS THAN 15 DEGREE, AND TRIED TO DRILL IT AGAIN. BUT IT DID NOT LOCK. THEREAFTER, WHEN THE SURGEON EXCHANGED WITH A NEW SCREW, IT LOCKED WITHOUT PROBLEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11376332 ↗MalfunctionJul 22, 2020Positioning Failure; Material Fragmentation; Positioning Failure; Material Fragmentation
IT WAS REPORTED: WHEN THE LOCKING SCREW WAS INSERTED INTO THE PLATE, THE SCREW THREAD WAS SCRAPED AND IT COULD NOT BE LOCKED. COLLECT THE SCREW AND DEBRIS. THE SURGEON INSERTED A NEW SCREW AND FINISHED THE OPERATION SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Known Impact Or Consequence To Patient
MAUDE report 10311168 ↗
Other PLATE, FIXATION, BONE devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-DRF32Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-PLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page