VARIAX 657355Recalls & reported problems
Stryker GmbH · Locking Screw · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327087406), received between Aug 4, 2025 and Aug 4, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Biocompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Biocompatibility1
Patient problems
- Erosion1
- Foreign Body Reaction1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 4, 2025Biocompatibility; Biocompatibility
AS REPORTED: "SURGEON ADVISED HE WAS REMOVING ONE OF OUR VARIAX FIBULA PLATES THAT HE HAD IMPLANTED 5 YEARS PRIOR & AT THE PLATE BONE INTERFACE AS PER ATTACHED PHOTO THERE WAS "GROSS METALLOSIS" AND "PRETTY BAD BONE EROSION" PLATE AND SCREWS HAVE BEEN SUCCESSFULLY REMOVED & WILL BE RETURNED ONCE DECONTAMINATED. SWABS HAVE BEEN SENT TO LOCAL PATHOLOGY."
Patient problems: Erosion; Foreign Body Reaction
MAUDE report 22701635 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page