VARIAX 657360Recalls & reported problems
Stryker GmbH · Locking Screw · Class 2 · Implant
All models of VARIAX (345)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327087437), received between May 22, 2018 and May 22, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device Inoperable” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Device Inoperable1
- Device Slipped1
Patient problems
- No Information1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2018Device Inoperable
PRIMARY PROCEDURE, RIGHT PROXIMAL ULNA. IT WAS REPORTED THAT IN INSERTING A VARI-AX 2 CORE LOCKING SCREW INTO THE PLATE, THE SCREW WOULD NOT LOCK. THE SURGEON REMOVED THE SCREW AND TRIED ANOTHER. THE SECOND SCREW WOULD NOT LOCK. A DIFFERENT PLATE WAS IMPLANTED AND VARI-AX (NOT VARI-AX 2) LOCKING SCREWS WERE USED. THE SCREWS LOCKED INTO THE PLATE. AT THE BACK TABLE, THE HEADS OF THE FIRST 2 SCREWS APPEARED TO BE COMPROMISED. A THIRD VARI-AX 2 LOCKING SCREW WAS INSPECTED AND FOUND TO BE FREE OF DEFECT. WHEN INSERTING THE SCREW INTO THE PLATE, IT WOULD NOT LOCK. THE SCREW WAS REMOVED AND THE HEAD APPEARED TO BE COMPROMISED. A VARI-AX SCREW WAS THEN INSERTED IN THE SAME HOLE AS THE FIRST SCREWS AND IT LOCKED WITH NO ISSUE. REP REPORTED A SURGICAL DELAY OF APPROXIMATELY 30-40 MINUTES. REP REPORTED VIA PHONE THAT THE THIRD SCREW WAS DISCARDED.
Patient problems: No Information
MAUDE report 7531490 ↗MalfunctionMay 22, 2018Device Slipped
PRIMARY PROCEDURE, RIGHT PROXIMAL ULNA. IT WAS REPORTED THAT IN INSERTING A VARI-AX 2 CORE LOCKING SCREW INTO THE PLATE, THE SCREW WOULD NOT LOCK. THE SURGEON REMOVED THE SCREW AND TRIED ANOTHER. THE SECOND SCREW WOULD NOT LOCK. A DIFFERENT PLATE WAS IMPLANTED AND VARI-AX (NOT VARI-AX 2) LOCKING SCREWS WERE USED. THE SCREWS LOCKED INTO THE PLATE. AT THE BACK TABLE, THE HEADS OF THE FIRST 2 SCREWS APPEARED TO BE COMPROMISED. A THIRD VARI-AX 2 LOCKING SCREW WAS INSPECTED AND FOUND TO BE FREE OF DEFECT. WHEN INSERTING THE SCREW INTO THE PLATE, IT WOULD NOT LOCK. THE SCREW WAS REMOVED AND THE HEAD APPEARED TO BE COMPROMISED. A VARI-AX SCREW WAS THEN INSERTED IN THE SAME HOLE AS THE FIRST SCREWS AND IT LOCKED WITH NO ISSUE. REP REPORTED A SURGICAL DELAY OF APPROXIMATELY 30-40 MINUTES. REP REPORTED VIA PHONE THAT THE THIRD SCREW WAS DISCARDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7531483 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.