AXSOS 627233SRecalls & reported problems

Stryker GmbH · Proximal Lateral Humerus Plate, RIGHT · Class 2 · Implant

All models of AXSOS (184)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07613327091243), received between Oct 28, 2020 and Sep 25, 2025 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1
  • Malposition of Device1
  • Material Integrity Problem1
  • Positioning Failure1

Patient problems

  • Failure of Implant1
  • Joint Dislocation1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjurySep 25, 2025Malposition of Device; Malposition of Device

    AS REPORTED: "PATIENT UNDERWENT ORIF FOR HUMERAL FRACTURE ON (B)(6) 2025. AXSOS PH IMPLANTED. THE PATIENT HAD TO UNDERGO REVISION SURGERY DUE TO RE-DISLOCATION OF THE BONY FRAGMENT OF THE GREATER TUBEROSITY OF THE HUMERUS DUE TO MALPOSITIONING OF THE PLATE."

    Patient problems: Joint Dislocation

    MAUDE report 23144615 ↗
  • InjuryAug 27, 2021Fracture; Material Integrity Problem; Fracture; Material Integrity Problem

    IT WAS REPORTED THE HOLES FOR K-WIRE/SUTURE ON A STRYKER PROXIMAL HUMERUS PLATE HAVE A FIBER WIRE TORN/SNAPPED. THE DEVICE WAS IMPLANTED ON TUBERCLE MINUS TO FIX/FIXATE ON THE PROXIMAL HUMERUS. THE ISSUE WAS OBSERVED DURING A REVISION SURGERY PERFORMED ON (B)(6) 2021. THE REVISION SURGERY WAS PERFORMED BECAUSE DURING THE PRIMARY OPERATION THE REPOSITION OF THE FRAGMENTS NEEDED TO BE DONE AGAIN.

    Patient problems: Failure of Implant

    MAUDE report 12377684 ↗
  • MalfunctionOct 28, 2020Positioning Failure; Positioning Failure

    AS REPORTED: "THE THIRD ROW FROM THE PROXIMAL POSITION, BUT IT DID NOT LOCK AND I REINSERTED ANOTHER LOCKING SCREW, BUT IT DID NOT LOCK. AFTER ALL, THE SCREW WAS INSERTED WITHOUT LOCKING. OTHER SCREW HOLES ARE FINE."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10748749 ↗

Other Plate, fixation, bone devices

All Plate, fixation, bone devices →