XIA PRECISION 48230230Recalls & reported problems
Stryker Corporation · K-WIRE SHARP · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327265026), received between Aug 9, 2016 and Aug 9, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 9, 2016Difficult to Remove
IT WAS REPORTED THAT; SURGEON WAS PASSING A PRECISION SCREW OVER A GUIDE WIRE INTO A PEDICLE - AND ONCE PLACED, THE K-WIRE WAS UNABLE TO BE REMOVED BY HAND. THE SURGEON THEN USED A LARGE NEEDLE DRIVER TO GRASP THE GUIDEWIRE, AND PULLED AND BACKED OUT THE SCREW AT THE SAME TIME TO REMOVE IT COMPLETELY. WE THEN EXAMINED THE SCREW AND FOUND THE TIP TO BE DAMAGED AND PARTIALLY FIXED TO THE WIRE. THE SCREW AND GUIDEIRE WERE REPLACED AND SURGERY CONTINUED, COMPLETED SUCCESSFULLY. THE CASE WAS DELAYED BY ABOUT 5 MINUTES WHILE WE RESOLVED THE ISSUE. THE GUIDEWIRE UNFORTUNATELY IS UNABLE TO BE RETURNED DUE TO ACCIDENTALLY BEING THROWN AWAY IN A SHARPS BIN BY A TECH ON-SITE PRIOR TO MY CATCHING IT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5858421 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page