MANTIS Redux 48289305Recalls & reported problems
Stryker Corporation · CANNULATED ROUND HANDLE NON-RATCHET · Class 1
All models of MANTIS Redux (6)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327266948), received between Jan 17, 2018 and Jan 25, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
- Fracture2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 25, 2018Break; Fracture; Fracture
IT WAS REPORTED THAT: ARTHRODESIS PROCEDURE, PATIENT OPERATED. INSTALLATION AND POSITIONING OF THE PATIENT. PREPARING THE PEDICLE SIGHT WITH JAM SHIDI TROCAR . WHEN THE DOCTOR WANTED TO IMPLANT THE SCREW THROUGH THE PEDICLE WITH THE SCREWDRIVER, THE HANDLE BROKE AT THE RACK. HE HAD TO USE ANOTHER HANDLE TO COMPLETE THE PROCEDURE. THERE WAS A DELAY OF ABOUT 5-10 MINUTES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7220397 ↗MalfunctionJan 17, 2018Break; Fracture; Fracture
IT WAS REPORTED THAT; OR MANAGER AT THE CLINIC, REPORTED THE FOLLOWING EVENT TO , SALES REP : "ARTHRODESIS PROCEDURE, PATIENT OPERATED BY DOCTOR. INSTALLATION AND POSITIONING OF THE PATIENT WAS PERFORMED. WHILE PREPARING THE PEDICLE SIGHT WITH JAM SHIDI TROCAR, HE WANTED TO IMPLANT THE SCREW THROUGH THE PEDICLE WITH THE SCREWDRIVER, THE HANDLE BROKE AT THE RACK. HE HAD TO USE ANOTHER HANDLE TO COMPLETE THE PROCEDURE. THERE WAS A DELAY OF ABOUT 5-10 MINUTES."
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7199459 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page