Skip to content

RADIUS 486619035Recalls & reported problems

Stryker Corporation · SHARP PROBE CURVED · Class 1

All models of RADIUS (13)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327275780), received between May 2, 2018 and May 31, 2018 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Break2
  • Fracture2
  • Detachment Of Device Component1

Patient problems

  • No Known Impact Or Consequence To Patient2
  • No Code Available1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 31, 2018Break; Detachment Of Device Component; Fracture; Fracture

    IT WAS REPORTED THAT THE DISTAL END OF PEDICLE PROBE BROKEN OFF IN PATIENT BONE. THIS OCCURRED IN THE S1 VERTEBRAL BODY WHILE SURGEON WAS PREPARING THE BONE FOR PEDICLE SCREW PLACEMENT. THERE ARE NO REPORTS OF ADVERSE HEALTH CONSEQUENCES TO THE PATIENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7558620 ↗
  • MalfunctionMay 2, 2018Fracture; Break; Fracture

    IT WAS REPORTED THAT WHILE PREPARING THE RIGHT L4, THE PEDICLE FINDER TIP BROKE OFF. THE TIP WAS RETRIEVED USING A CLAMP FROM A SCREW REMOVAL SET. THERE WAS A 20 MINUTE SURGICAL DELAY. THERE ARE NO REPORTS OF ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Code Available; No Known Impact Or Consequence To Patient

    MAUDE report 7479076 ↗

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page