AVS Anchor-C Cervical Cage System 48328625ARRecalls & reported problems
Stryker Corporation · REPLACEMENT SCREW EXTRACTOR DRAW ROD · Class 1
All models of AVS Anchor-C Cervical Cage System (8)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327276848), received between Feb 9, 2016 and Feb 9, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Detachment Of Device Component1
- Fracture1
- Material Integrity Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 9, 2016Fracture; Material Integrity Problem; Break; Detachment Of Device Component; Fracture; Material Integrity Problem
IT WAS REPORTED THAT THE SURGEON ATTEMPTED TO REMOVE A SCREW FROM A CAGE THAT WAS IMPLANTED. HE USED A REMOVAL DRIVER THAT COMES IN THE SET BUT WAS UNABLE TO GET THE SCREWDRIVER TO CONNECT INTO THE SCREW WITH THE DRAW ROD. HE LEFT THE SCREW IN PLACE AND DID NOT ATTEMPT TO REMOVE IT AGAIN. HE THEN NOTICED THAT THE TIP OF THE DRAW ROD WAS BROKEN OFF AND HE SAID IT WAS STUCK IN THE SCREW. THE SURGEON WAS NOT WORRIED ABOUT IT COMING OUT AND CLOSED THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 5419795 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page