NA 2358-3200Recalls & reported problems
Stryker GmbH · Bone Plug Extractor · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327346466), received between Sep 17, 2020 and Sep 23, 2020 — classified as 2 injuries.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- Bone Fracture(s)1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 23, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
SURGEON TREATED A CHRONIC CHARCOT FOOT IN A MEDIAL COLUMN PROCEDURE AND PROVIDED THE FOLLOWING FEEDBACK: ¿CROWN DRILL AND BONE PLUG SEEMED INTUITIVE BUT IT WAS A LITTLE STRUGGLE.¿ ADDITIONAL INFO RECEIVED: "THE STRUGGLE WITH THE CROWN DRILL / BONE PLUG EXTRACTOR WAS IT WAS TOO BIG FOR THE PATIENT AND FRACTURED THE PROXIMAL PORTION OF THE 1ST MET HEAD. IT DID NOT ALTER THE OUTCOME OF THE CASE."
Patient problems: Bone Fracture(s)
MAUDE report 10576706 ↗InjurySep 17, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
SURGEON TREATED A CHRONIC CHARCOT FOOT IN A BOTH COLUMNS PROCEDURE ON A PATIENT THAT HAD PREVIOUSLY BEEN TREATED WITH AN EXTERNAL FIXATOR. HIS FEEDBACK INCLUDED THE FOLLOWING: "THE 1ST MET BONE PLUG WE REMOVED WAS TOO LARGE. I THINK PRIOR TO RE-INSERTING YOU SHOULD MEASURE THE DEPTH + CUT TO SIZE. TRYING TO TAMP THE LARGE PLUG BACK IN DESTROYED THE CARTILAGE OF THE JOINT.¿ [PROVIDED AS A COMMENT ON ANY DISSATISFACTION WITH THE PRODUCTS AND PROCEDURE].
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10550775 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page