NA 2351-4213SRecalls & reported problems

Stryker GmbH · Freehand Drill · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 07613327350289), received between Aug 7, 2023 and Feb 6, 2026 — classified as 3 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Fracture” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture6
  • Break5
  • Mechanical Jam1
  • Noise, Audible1
  • Off-Label Use1

Patient problems

  • Foreign Body In Patient5
  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 6, 2026Fracture

    THE CUSTOMER REPORTED THAT: "WHILE WASHING THE ANCILLARY EQUIPMENT IN STERILIZATION, THE STERILIZATION AGENT NOTICED THAT A PIECE WAS MISSING FROM THE T2 ALPHA STRYKER DRILL REF (B)(4). CHECK THE PATIENT'S X-RAY, WHERE YOU CAN SEE THE PIECE OF DRILL NEXT TO THE SCREW. NO REOPERATION IN THE OPERATING ROOM IS NECESSARY, ACCORDING TO THE SURGEON. PATIENT DISCHARGED ON (B)(6) 2026 WITH NO COMPLICATIONS SO FAR. NO INTERVENTION TO REMOVE THE TIP IS NECESSARY AT THIS TIME.".

    Patient problems: Foreign Body In Patient

    MAUDE report 24280477 ↗
  • InjuryJun 6, 2024Break; Fracture; Break; Fracture

    THE CUSTOMER REPORTED: "2 DRILL BITS BROKE DURING A FEMORAL NAIL PROCEDURE. THE PIECES OF DRILL BIT REMAINED IN THE PATIENT WITHOUT CONSEQUENCE."

    Patient problems: Foreign Body In Patient

    MAUDE report 19477289 ↗
  • InjuryJun 6, 2024Break; Fracture; Break; Fracture

    THE CUSTOMER REPORTED: "2 DRILL BITS BROKE DURING A FEMORAL NAIL PROCEDURE. THE PIECES OF DRILL BIT REMAINED IN THE PATIENT WITHOUT CONSEQUENCE.".

    Patient problems: Foreign Body In Patient

    MAUDE report 19477177 ↗
  • MalfunctionDec 1, 2023Break; Fracture; Break; Fracture

    IT WAS REPORTED THAT DURING A TIBIAL NAIL PROCEDURE, DRILL BIT BROKE OFF AT TIP. MULTIPLE ATTEMPTS MADE TO RETRIEVE, BUT UNSUCCESSFUL. RETAINED DRILL BIT IN PATIENT.

    Patient problems: Foreign Body In Patient

    MAUDE report 18246760 ↗
  • MalfunctionSep 29, 2023Break; Fracture; Break; Fracture

    AS REPORTED: "THE SHORT ALPHA DISTAL LOCKING DRILL SNAPPED AT THE TIP DURING THE DRILLING OF THE DISTAL SCREWS IN A T2 ALPHA TIBIAL NAIL."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17847853 ↗
  • MalfunctionAug 21, 2023Break; Fracture; Noise, Audible; Break; Fracture; Noise, Audible

    AS REPORTED: "WHEN DRILLING FOR 2ND LOCKING SCREW IN MOST DISTAL M/L HOLE A NOTABLE CHATTER COULD BE HEARD. FOLLOWING WHICH THE TIP OF THE DRILL BROKE OFF WHERE IT TAPERS DOWN AND TIP FRAGMENT WAS THEN SITUATED ON THE MEDIAL SIDE OF THE NAIL WITHIN THE PATIENT. BROKEN DRILL WAS REMOVED AND THE DECISION WAS MADE TO LEAVE THE TIP FRAGMENT IN SITU. SECOND DISTAL LOCKING WAS THEN PERFORMED USING THE A/P HOLE AND A NEW DRILL FROM THE SAME LOT WITH NO ISSUES."

    Patient problems: Foreign Body In Patient

    MAUDE report 17584665 ↗
  • MalfunctionAug 7, 2023Off-Label Use; Mechanical Jam; Off-Label Use; Mechanical Jam

    AS REPORTED: "THE SERVICE&REPAIR CENTER IN THE NETHERLANDS REPORTED A STRYKER DRILL BIT FOUND STUCK IN A DEPUY SYNTHES ATTACHMENT. THE ATTACHMENT ISN'T WORKING PROPERLY; THE CUSTOMER DIDN'T PROVIDE FURTHER INFORMATION.¿

    Patient problems: Insufficient Information

    MAUDE report 17470516 ↗

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →