GAMMA 8425-0320SRecalls & reported problems
Stryker GmbH · Long Nail, RIGHT · Class 2 · Implant
All models of GAMMA (249)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07613327479515), received between Mar 20, 2025 and Mar 23, 2026 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- May 28, 2025Class IIOpen, Classified
Investigation confirmed that the GAMMA4 Right Long Nail was manufactured with the geometry of a left nail.
Z-1914-2025 · Root cause: Process design · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Fracture1
- Malposition of Device1
- Positioning Failure1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
- Perforation1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMar 23, 2026Fracture
AS REPORTED: "THE DISTRIBUTOR CONTACTED THE SALES REPRESENTATIVE TO REPORT THAT A GAMMA4 NAIL USED ON A PATIENT HAD BROKEN."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24670110 ↗InjuryDec 11, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT "DURING INSERTION OF A GAMMA 4 LONG NAIL FOR A SUBTROCHANTERIC FEMORAL FRACTURE, THE NAIL TIP PERFORATED THE ANTERIOR ASPECT OF THE FEMUR AT THE UPPER FEMORAL CONDYLE. THE ENTRY WAS REPOSITIONED ANTERIORLY AND THE NAIL WAS REINSERTED DEEPLY. THE SURGERY WAS COMPLETED. THE DEVICE IS IMPLANTED IN THE PATIENT'S BODY".
Patient problems: Insufficient Information
MAUDE report 23783832 ↗MalfunctionMar 20, 2025Positioning Failure; Malposition of Device; Positioning Failure; Malposition of Device
AS REPORTED: "OPENED THE RIGHT NAIL OF GAMMA 4 DIAMETER 10MM / LENGTH 320MM. LUG SCREW INTERFERENCE CHECK WAS PERFORMED. AFTER INSERTING THE NAIL AND LAG SCREW, THE DISTAL DEVICE WAS ATTACHED, AND AFTER ADJUSTING THE HEIGHT, THE MOST DISTAL CIRCULAR HOLE WAS DRILLED, BUT AFTER PASSING THROUGH THE FRONT HOLE, THE DRILL DID NOT PASS THROUGH DUE TO INTERFERENCE INSIDE THE NAIL. AFTER THAT, WE TRIED THE DISTAL MOST ROUND HOLE AND THE ELLIPTICAL HOLE, BUT THE DRILLS DID NOT PASS THROUGH ALL OF THEM. WHEN THE C-ARM WAS INSERTED FROM RIGHT BESIDE THE DISTAL END OF THE NAIL TO SWITCH TO RADIOLUCENT, IT WAS DISCOVERED THAT THE CUT SURFACE AT THE DISTAL END OF THE NAIL WAS NOT FORWARD, BUT BACKWARD. AFTER REMOVING THE NAIL, A NAIL ONE SIZE SHORTER (300 MM) WAS REINSERTED. SURGERY WAS COMPLETED. AFTER SURGERY, THE DISTAL DEVICE AND NAIL WERE INSTALLED AND CALIBRATED, AND THE DRILL DID NOT PASS".
Patient problems: Hemorrhage/Blood Loss/Bleeding; Perforation
MAUDE report 21659994 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page