PANGEA 541037Recalls & reported problems
Stryker GmbH · 3.5 Straight Narrow Plate · Class 2 · Implant
All models of PANGEA (53)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327606522), received between Nov 24, 2025 and Nov 24, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Device Difficult to Setup or Prepare1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 24, 2025Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED: "THE PRODUCTS IN QUESTION ARE THE 3.5MM NARROW COMPRESSION PLATE T15, (541037 7 HOLE PLATE FOR EXAMPLE) AND THE SHORTER T15 CORTICAL SCREWS (661412 12MM SCREW FOR EXAMPLE). I WATCHED THE SURGEON DRILL THROUGH BOTH CORTICES ONCE USING THE VA GUIDE (542028) IN WHAT LOOKED LIKE A PERPENDICULAR TO THE PLATE TRAJECTORY. WE CONFIRMED IT WAS A 2.5MM DRILL USED. THE SCREW WOULD CONTINUE TO SPIN IN THE HOLE UPON INSERTION, THIS HAPPENED TWICE. WE THEN USED A LONGER SCREW AND THE SAME HAPPENED AGAIN. THE SURGEON THINKS IT'S BECAUSE THE PITCH OF THE SCREWS ARE INFERIOR AND HENCE ON SMALLER LENGTHS THEY DON'T GET AS GOOD AS PURCHASE AS WHAT HE USES. ANOTHER COMMENT WAS THAT THE SCREW HEAD LOOKED TOO SMALL COMPARED TO THE DCP HOLE. THIS WAS A PROBLEM WHEN A SCREW WAS INSERTED ON AN ANGLE AWAY FROM THE FRACTURE SITE. THE SURGEON FOUND THAT UPON TIGHTENING THE CORTICAL SCREW IN THIS TRAJECTORY THAT THE SPACE BETWEEN THE SCREW HEAD AND THE BOTTOM OF THE PLATE WAS VERY LOW AND HE WAS WORRIED ABOUT SCREW PULL THROUGH ON THE PLATE."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23639301 ↗
Other Screw, fixation, bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-200Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page