Breathing circuit set, dual limb 260170Recalls & reported problems

Hamilton Medical AG · Dual limb breathing circuit set with Swivel Y-piece, neonatal flow sensor, neonatal expiratory valve set and pressure line for use with HAMILTON-C1/T1/MR1, 150 cm, neonatal, single-use · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630002805902), received between Jan 29, 2024 and Jan 29, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Connection Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Connection Problem1
  • Fitting Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 29, 2024Fitting Problem; Connection Problem; Fitting Problem; Connection Problem

    THE FOLLOWING WAS REPORTED TO HAMILTON MEDICAL AG: - THIS EVENT WAS REPORTED TO HAMILTON AS THE BREATHING CIRCUIT SET COULD NOT BE CONNECTED TO THE CPAP MASK (FOR CHILDREN). - THIS OCCURRENCE WAS NOTICED WHEN THE PATIENT NEEDED TO BE CONNECTED FOR VENTILATION. - AS A RESULT OF STRUGGLING TO CONNECT THE BREATHING MASK TO THE BREATHING CIRCUIT, SOME VENTILATOR ALARMS WERE ACTIVATED. - THE DEVICE LOG FILES WERE NOT PROVIDED TO HAMILTON. - THERE IS PATIENT INVOLVEMENT REPORTED (INFANT, 20 MONTHS OLD, 9KG). - THERE WAS NEED FOR MEDICAL INTERVENTION REPORTED. THE VENTILATOR DEVICE AND THE BREATHING CIRCUIT SET GOT REPLACED. - NEITHER HARM TO THE PATIENT, USER OR THIRD PARTY HAS BEEN REPORTED. THERE IS NO DELAY IN TREATMENT REPORTED AS SUCH BUT BASED ON THE INFORMATION WHAT HAS BEEN REPORTED, IT CAN BE CONCLUDED THAT THIS EVENT CAUSED A CERTAIN DEGREE OF UNCERTAINTY BETWEEN THE HOSPITAL STAFF. THE INVESTIGATION IS ONGOING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18594401 ↗

Other Set, Tubing And Support, Ventilator (W Harness) devices

All Set, Tubing And Support, Ventilator (W Harness) devices →