MectaLIF Anterior System 03.30.126Recalls & reported problems
Medacta International SA · Screw Diam.5.5x35 (Double Packaging) · Class 2 · Implant
All models of MectaLIF Anterior System (12)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630030833540), received between Mar 16, 2018 and Mar 16, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 16, 2018Break; Break
WHEN THE LAST SCREW WAS PUT IN PLACE, AN IMAGE WAS TAKEN AND THE SURGEON WAS NOT FULLY SATISFIED WITH THE POSITION OF THAT SCREW. WHEN ATTEMPTING TO REVERSE AND REPOSITION THE SCREW, THE HEAD OF THE SCREW BROKE. THE SURGEON DID NOT OVER-ANGLE THE SCREWDRIVER AND THERE WERE NO INCORRECT PROCEDURAL STEPS IN THE OPERATION. EVERYTHING WAS PERFECTLY FINE AND WELL DONE. THERE WAS NO DANGER FOR THE PATIENT AND THE REST OF THE SCREW HAD GOOD FIXATION, SO THE REMAINING PORTION OF THE SCREW WAS LEFT IN PLACE. THE INVOLVED SCREW WAS NOT IMPLANTED WITH THE TORQUE LIMITER.
Patient problems: No Code Available
MAUDE report 7344702 ↗
Other Intervertebral Fusion Device With Integrated Fixation, Lumbar devices
- PIVOX™ Oblique Lateral Spinal System 2161001Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, lumbar182 reports
- IdentiTi 232-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall8 reports
- IdentiTi 232-10-85-250Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall5 reports
- IdentiTi 132-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall3 reports
- MectaLIF Anterior 03.30.301Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall2 reports
- IdentiTi 232-10-85-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall2 reports
- IdentiTi 232-11-90-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall1 report
- MectaLIF Anterior 03.30.302Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page