Bipolar Heads 25060.2846Recalls & reported problems

Medacta International SA · Ø28x46 · Class 2 · Implant

All models of Bipolar Heads (15)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07630030843631), received between Jul 20, 2018 and Jul 10, 2026 — classified as 8 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated6
  • Adverse Event Without Identified Device or Use Problem1
  • Appropriate Device Problem Term/Code Not Available1
  • Patient-Device Incompatibility1

Patient problems

  • Joint Dislocation5
  • Unspecified Infection2
  • Pain1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 10, 2026Device Dislodged or Dislocated

    REVISION SURGERY DUE TO JOINT LUXATION BETWEEN BIPOLAR HEAD AND ACETABULUM AFTER ABOUT 2 MONTHS FROM PRIMARY. THE SURGEON REVISED THE HEMI HIP TO A TOTAL HIP.

    Patient problems: Joint Dislocation

    MAUDE report 25778122 ↗
  • InjuryMay 25, 2026Device Dislodged or Dislocated

    AT ABOUT 1 MONTHS FROM THE PRIMARY,THE PATIENT PRESENTED WITH PAIN DUE TO A DISLOCATION OF THE BI-POLAR HEAD FROM THE FEMORAL HEAD FOLLOWING A FALL. THE SURGEON REVISED THE BI-POLAR HEAD WITH ANOTHER ONE OF THE SAME SIZE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 25268618 ↗
  • InjuryFeb 16, 2026Device Dislodged or Dislocated

    THE PATIENT HAD PAIN FROM CHRONIC DISLOCATIONS (BIPOLAR HEAD FROM ACETABULUM BONE) POSTERIORLY AND THE CAUSE IS UNKNOWN. THE DISLOCATIONS WERE TREATED WITH CLOSED REDUCTION. FINALLY, THE SURGEON REVISED THE HIP FROM A HEMI TO A FULL HIP REPLACEMENT AFTER 6 YEARS AND 2 MONTHS FROM THE PRIMARY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 24343896 ↗
  • InjuryOct 23, 2020Device Dislodged or Dislocated; Appropriate Device Problem Term/Code Not Available

    THE PATIENT CAME IN REPORTING PAIN, 2 TWO MONTHS AFTER THE PRIMARY SURGERY, DUE TO A DISLOCATION OF THE BIPOLAR HEAD FROM THE ACETABULUM. THE SURGEON REVISED THE BIPOLAR HEAD SIZE 28X46 WITH A BIPOLAR HEAD SIZE 28X46 AND THE 28MM COCR HEAD M WITH A 28MM COCR HEAD L. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Joint Dislocation

    MAUDE report 10727243 ↗
  • InjuryJul 28, 2020Device Dislodged or Dislocated

    REVISION SURGERY PERFORMED DUE TO DISLOCATION OF THE BIPOLAR HEAD FROM ACETABULAR BONE. BALL HEAD, HEAD AND STEM WERE REVISED 1 MONTH AFTER PRIMARY. THE PATIENT FELL BUT IT IS NOT KNOWN IF THE PATIENT FELL AND LUXATED OR VICE-VERSA.

    Patient problems: Joint Dislocation

    MAUDE report 10331240 ↗
  • InjuryJun 17, 2020Device Dislodged or Dislocated

    THE PATIENT CAME IN REPORTING PAIN DUE TO A DISASSOCIATION OF THE BIPOLAR HEAD FROM THE BIOLOX HEAD THAT WAS CAUSED WHEN THE PATIENT WAS GETTING OUT OF BED. THE SURGEON CONVERTED THE PATIENT FROM A BIPOLAR HIP TO A TOTAL HIP 3 MONTHS AFTER PRIMARY. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Pain

    MAUDE report 10161542 ↗
  • InjuryJan 16, 2019Patient-Device Incompatibility

    ABOUT 1 MONTH AFTER PRIMARY FOR AN INFECTION CASE THE SURGEON SURGEON WASHED OUT THE HIP AND REVISED THE BIPOLAR HEAD AND COCR HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 8252592 ↗
  • InjuryJul 20, 2018Adverse Event Without Identified Device or Use Problem

    THE PATIENT CAME IN DUE TO SIGNS OF INFECTION 1 MONTH AFTER PRIMARY. THE PATHOGEN CONFIRMED AS ENTEROCOCCUS FAECALIS. THE SURGEON WASHED OUT THE HIP AND REVISED THE BIPOLAR HEAD AND COCR HEAD. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: Unspecified Infection

    MAUDE report 7706393 ↗

Other Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented devices

All Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented devices →