MectaLIF Anterior System 03.30.133Recalls & reported problems
Medacta International SA · Enhanced Screw Diam.5x35 (Double Packaging) · Class 2 · Implant
All models of MectaLIF Anterior System (12)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 07630030875434), received between Jun 8, 2018 and Dec 16, 2022 — classified as 1 injury, 5 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break4
- Fracture3
Patient problems
- No Known Impact Or Consequence To Patient4
- Foreign Body In Patient1
- Insufficient Information1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryDec 16, 2022Fracture; Fracture
THE SURGEON NOTED AFTER SURGERY THAT THE S1 SCREW HAD BROKEN. THE SURGEON THERE WAS NOT A COMPLETE FUSION ACROSS THE CAGE AND EVENTUALLY DECIDED TO FURTHER STABILIZE THE PATIENT WITH POSTERIOR FIXATION, ABOUT 3 YEARS AND 5 MONTHS AFTER THE PRIMARY SURGERY.
Patient problems: Insufficient Information
MAUDE report 15994328 ↗MalfunctionSep 3, 2019Fracture; Fracture
THE PATIENT CAME IN FOR A POST-OP X-RAY 2 MONTHS AND 10 DAYS AFTER PRIMARY AND IT WAS OBSERVED THAT AN ALIF SCREW HAD FRACTURED. THE REASON FOR THE SCREW FRACTURE IS UNKNOWN. THE SURGEON DOES NOT PLAN ON REVISING THE PATIENT AT THIS TIME, BUT WILL MONITOR THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8955164 ↗MalfunctionSep 2, 2019Break; Fracture; Break; Fracture
THE PATIENT CAME IN FOR A POST-OP X-RAY 5 MONTHS AND 2 DAYS AFTER PRIMARY AND IT WAS OBSERVED THAT AN ALIF SCREW HAD FRACTURED. THE REASON FOR THE SCREW FRACTURE IS UNKNOWN. THE SURGEON DOES NOT PLAN ON REVISING THE PATIENT AT THIS TIME, BUT WILL MONITOR THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8953780 ↗MalfunctionSep 2, 2019Break; Break
THE PATIENT CAME IN COMPLAINING OF PAIN DUE TO A SCREW FRACTURE. DURING THE PRIMARY SPINE SURGERY, A LARGE ANTERIOR OSTEOPHYTE WAS PRESENT AND IMPEDED THE CAGE TO BE PLACED ALL THE WAY POSTERIOR TOWARDS THE BACK OF THE VERTEBRAL BODY. THE IMPLANT WAS PROUD ANTERIORLY AND NOT IN AN IDEAL POSITION. THE PATIENT WAS ALSO FRACTURED IN THE ANTERIOR SUPERIOR CORNER OF S1. THE PATIENT DID NOT SUSTAIN ANY ADDITIONAL SUBSIDENCE OR INSTABILITY. THE SURGEON DOES NOT PLAN ON REVISING THE PATIENT AT THIS TIME, BUT WILL MONITOR THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8953728 ↗MalfunctionJul 5, 2019Break; Break
SPINE SCREW BREAKAGE AFTER ABOUT 1 YEAR AND 7 MONTHS FROM PRIMARY SURGERY. NO EVIDENCE OF REVISION SURGERY PERFORMED FOR THE MOMENT. THE PATIENT HAD A REVISION SURGERY FEW DAYS AFTER PRIMARY TO PUT L5 ENDPLATE AND TO SHORTEN S1 SCREW SITTING IN THE FORAMEN, THE SURGEON ONLY SWAPPED OUT 1 SCREW AS HE WAS UNHAPPY WITH SIZE HE ORIGINALLY USED. THE PRIMARY SURGERY HAS BEEN PERFORMED ON THE (B)(6) 2017.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8764337 ↗MalfunctionJun 8, 2018Break; Break
DURING THE FINAL TIGHTENING TWO SCREW HEADS BROKE. THE PATIENT HAS VERY SCLEROTIC BONE AND THE SURGEON DIDN'T USE THE TORQUE LIMITER BECAUSE HE NEEDED AN HIGHER TORQUE. THE SCREWS WERE LEAVED IN THE PATIENT AND THE SCREW HEADS RECOVERED.
Patient problems: Foreign Body In Patient
MAUDE report 7582498 ↗
Other Intervertebral Fusion Device With Integrated Fixation, Lumbar devices
- PIVOX™ Oblique Lateral Spinal System 2161001Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, lumbar182 reports
- IdentiTi 232-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall8 reports
- IdentiTi 232-10-85-250Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall5 reports
- IdentiTi 132-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall3 reports
- MectaLIF Anterior 03.30.301Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall2 reports
- IdentiTi 232-10-85-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall2 reports
- IdentiTi 232-11-90-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall1 report
- MectaLIF Anterior 03.30.302Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page