Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630040713986), received between Dec 4, 2023 and Dec 4, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 4, 2023Fracture; Fracture

    THE SURGEON WANTED TO USE A 30MM/11 TIBIA STEM ON A PATIENT WHO WAS PERFORMING AN LTK, BUT THE EXTENSION SET WAS NOT AVAILABLE DURING SURGERY, SO WE USED THE METAL STEM TRIAL ON THE EFFICIENCY KEEL GRAY HANDLE. THE THREADED PART OF THE TRIAL KEEL S3-4 BROKE INTO THE METAL TRIAL STEM. THE SURGEON WAS NOT ABLE TO REMOVE THE BROKEN PART OF THE KEEL, SO THE SURGERY WAS COMPLETED LEAVING THE TRIAL STEM INSIDE THE PATIENT'S BONE. A NEW KEEL WAS USED AND IT WAS POSSIBLE TO PUNCH IT INTO THE TRIAL BASEPLATE; THE TRIAL STEM WAS PUSHED SLIGHTLY DOWN SO THAT THERE WAS ROOM FOR THE FINAL TIBIA BASEPLATE. A DELAY OF 25 MINUTES OCCURRED ON A TOTAL SURGERY TIME OF ABOUT 1 HOUR AND 25 MINUTES. NO REVISION SURGERY IS CURRENTLY PLANNED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18254241 ↗