Hip Instruments 01.32.10.1156Recalls & reported problems

Medacta International SA · Impaction Plate DMH · Class 1

All models of Hip Instruments (48)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07630040753692), received between Apr 4, 2019 and Jul 10, 2019 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Material Fragmentation2
  • Solder Joint Fracture1

Patient problems

  • No Known Impact Or Consequence To Patient3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 10, 2019Material Fragmentation; Material Fragmentation

    DURING THE PRIMARY HIP SURGERY, AND AFTER IMPACTING THE CUP, THE SURGEON TRIED TO UNSCREW THE HANDLE AND IT WOULD NOT RELEASE. AFTER CONTINUOUSLY TRYING TO RELEASE THE HANDLE, THE PLATE BROKE INTO MANY PIECES. FRAGMENTS FELL INTO THE PATIENT AND WERE REMOVED. THERE WAS A 5-MINUTE DELAY AND THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8775348 ↗
  • MalfunctionApr 25, 2019Material Fragmentation; Material Fragmentation

    DURING THE PRIMARY HIP SURGERY AND AFTER IMPACTING THE CUP, IT WAS DISCOVERED THAT THE IMPACTION PLATE HAD BROKEN DURING IMPACTION. NO FRAGMENTS FELL INTO THE PATIENT'S SURGICAL WOUND AND THERE WAS NO DELAY IN THE CASE. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8548600 ↗
  • MalfunctionApr 4, 2019Solder Joint Fracture; Solder Joint Fracture

    DURING THE PRIMARY HIP SURGERY AND AFTER IMPACTING THE CUP, IT WAS DISCOVERED THAT THE IMPACTION PLATE BROKE AND A FRAGMENT FELL INTO THE PATIENT. THE SURGEON WAS ABLE TO REMOVE THE FRAGMENT AND THE CASE WAS DELAYED BY 3-MINUTES. THE SURGERY WAS COMPLETED SUCCESSFULLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8482792 ↗