Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630040760119), received between Sep 27, 2024 and Sep 27, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 27, 2024Use of Device Problem; Use of Device Problem
WHEN USING THE CROSSOVER INSTRUMENTATION, IT WAS NOTICED THAT THE REAMERS IN THE SLEEVES DO NOT HAVE PROPER GUIDANCE AS SOON AS THEY ARE INSERTED INTO THE SHAFT AND TEND TO DEVIATE. THIS CREATED PROBLEMS WHEN PLACING THE TRIALS AND THE FINAL IMPLANTS. THE SURGEON FIRST USED SAFE GUIDING REAMER Ø11MM, THEN SAFE GUIDING REAMER Ø13MM, ANF INALLY SAFE GUIDING REAMER Ø16MM. THE OPERATION TIME WAS EXTENDED BY ABOUT AN HOUR AND MORE ANESTHETIC HAD TO BE ADMINISTERED. ON THE TIBIA, THE TIBIA WAS INITIALLY NOT PLACED CLEANLY ON THE RESECTION BECAUSE THE SHAFT WAS DIVERTED. THE FEMUR WAS FLEXED AND HAD NO SECURE HOLD BY THE SHAFT. THIS HAD TO BE HELD IN PLACE FOR CEMENTATION, OTHERWISE IT WOULD NOT HAVE REMAINED IN THE CORRECT POSITION. NO DEFECTS CAN BE NOTED ON THE REAMERS. THE PATIENT WAS VERY YOUNG AND HAD HARD BONES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20320103 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page