Spine Instruments 03.22.10.7041Recalls & reported problems
Medacta International SA · Stopper sleeve 30 mm, Drill2.7 - Lumbar · Class 1
All models of Spine Instruments (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630971235847), received between Feb 26, 2020 and Feb 26, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 26, 2020Break
DURING THE PRIMARY SPINE SURGERY, WHILE THE SURGEON WAS PERFORMING L4/5 POSTERIOR LUMBER FUSION, AND WHEN PLACING BOTH THE L4/5 GUIDES, THE SURGEON HAD PLANNED TO PLACE 45MM SCREWS IN L4 AND 40 MM SCREWS IN L5 DUE TO THE TRAJECTORY FROM THE DRILLS HE WAS ONLY ABLE TO PLACE 35 MM SCREWS. IN ADDITION, WHEN THE SURGEON WENT TO CHECK AP FLUOROSCOPY PLACEMENT OF THE L4 RIGHT SIDED PEDICLE HE NOTICED A MEDIAL BREAK OF THE PEDICLE. THE SURGEON HAD DRILLED AND PLACED PEDICLE MARKERS, WHEN THIS WAS FOUND. AFTER PERFORMING HIS DECOMPRESSION, HE WENT BACK AND REVISED THE L4 SCREW TRAJECTORY WITH A FREE HAND APPROACH. THE TOTAL DELAY WITH THE GUIDES AND REPLACEMENT OF THE L4 SCREW WAS 20 MINUTES. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: Bone Fracture(s)
MAUDE report 9755013 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page