HIP Instruments 01.10.10.0845Recalls & reported problems
Medacta International SA · Bayonet drill bit Ø3.2mm L45 · Class 1
All models of Hip Instruments (48)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07630971251700), received between Dec 30, 2024 and Dec 30, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 30, 2024Break; Break
WHILE THE SURGEON WAS DRILLING TO INSERT THE SCREWS INTO THE CUP, THREE DIFFERENT BAYONET DRILL BITS BROKE. THE THIRD BROKEN DRILL GOT STUCK IN THE PATIENT (THE SMALLEST ONE). TO RETRIEVE IT, THE SURGEON HAD TO REMOVE THE CUP AND FELT MORE SECURE IN IMPLANTING A NEW ONE (SAME REF, DIFFERENT LOT). THE SCREWS WERE SUCCESSFULLY IMPLANTED WITH COMPETITOR DRILL BITS. 20-25 MIN DELAY REPORTED. PATIENT'S BONE QUALITY WAS HARD/SCLEROTIC. DRILL GUIDE WAS USED (CURVED DRILL GUIDE - GOLDEN TIP, REF 01.10.10.372).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21033592 ↗
Other Orthopedic Manual Surgical Instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page