PRIMO2XRecalls & reported problems
Sorin Group Italia Srl · Class 2
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08033178100687), received between Jan 10, 2018 and Jan 10, 2018 — classified as 1 death.
The most frequently reported specific device problem is “Low Readings” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Low Readings1
Patient problems
- Abnormal Blood Gases1
- Blood Loss1
- Death1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathJan 10, 2018Low Readings; Low Readings
SORIN GROUP (B)(4) RECEIVED A REPORT THAT A LOW PO2 VALUE WAS RECORDED FOR A PRIMO2X OXYGENATOR DURING A CIRCULATORY-ARREST CASE. THE USER REPORTEDLY CHECKED THE CONNECTIONS TO MAKE SURE GAS WAS FLOWING TO THE OXYGENATOR. THE FIO2 WAS TURNED UP AS THE PATIENT WAS COOLED TO 18°C AND THE PO2 DECLINED. AN O2 TANK WAS CONNECTED AS THE PATIENT WAS WARMED, BUT THEY WERE UNABLE TO REACH THE EXPECTED PO2 VALUE. THE OXYGENATOR WAS CHANGED OUT AND THE PATIENT WAS TAKEN OFF BYPASS. THE PATIENT EXPERIENCED SOME BLEEDING ISSUES AND REPORTEDLY EXPIRED ON (B)(6) 2017.
Patient problems: Abnormal Blood Gases; Blood Loss; Death
MAUDE report 7177927 ↗
Other OXYGENATOR, CARDIOPULMONARY BYPASS devices
- HLS Set BEQ-HLS 7050 USAMaquet Cardiopulmonary AG · Oxygenator, Cardiopulmonary Bypass3 recalls13 deaths90 reports
- Affinity Fusion® BB811Medtronic, Inc. · OXYGENATOR, CARDIOPULMONARY BYPASS2 recalls90 reports
- HLS Set BEQ-HLS 5050 USAMaquet Cardiopulmonary AG · Oxygenator, Cardiopulmonary Bypass3 recalls4 reports
- NA HLS Set Advanced 5.0, Small Adult, BIOLINE CoatingMaquet Cardiopulmonary AG · OXYGENATOR, CARDIOPULMONARY BYPASS3 recalls0 reports
- A.M.G. PMP Sterile A.M.G. Module PMP NO T.P. SterileEurosets Srl · Oxygenator, Cardiopulmonary Bypass2 deaths106 reports
- CAPIOX®FX CX*FX25RWTerumo Corporation · Oxygenator, Cardiopulmonary Bypass2 deaths102 reports
- CAPIOX®RX CX*RX25RWTerumo Corporation · Oxygenator, Cardiopulmonary Bypass1 death102 reports
- QUADROX-iD QUADROX-iD Adult, SOFTLINE Coating, without FilterMaquet Cardiopulmonary AG · OXYGENATOR, CARDIOPULMONARY BYPASS2 recalls0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.