Skip to content

BIO-FLASH 3710-0344Recalls & reported problems

Biokit, S.A. · BIO-FLASH · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 08426950639725), received between Dec 27, 2024 and Dec 27, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “False Negative Result” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • False Negative Result1
  • Insufficient Device Problem Information1

Patient problems

  • Kidney injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 27, 2024False Negative Result; Insufficient Device Problem Information; False Negative Result; Insufficient Device Problem Information

    THE QUANTA FLASH® GBM IS A CHEMILUMINESCENT IMMUNOASSAY (CIA) FOR THE SEMI-QUANTITATIVE DETECTION OF IGG ANTI-GLOMERULAR BASEMENT MEMBRANE (GBM) AUTOANTIBODIES IN HUMAN SERUM ON THE BIO-FLASH® INSTRUMENT. QUANTA FLASH® GBM IS AN AID IN THE DIAGNOSIS OF GOODPASTURE'S SYNDROME IN CONJUNCTION WITH CLINICAL FINDINGS AND OTHER LABORATORY TESTS. COMPLAINT (B)(4) REPORTED THAT A PATIENT WITH ACUTE KIDNEY INJURY PRESENTED WITH A NEGATIVE QUANTA FLASH GBM REAGENT (LOT NUMBER 244154) RESULT ON (B)(6) 2024. ON (B)(6) 2024 THE SAMPLE WAS RETESTED USING THE PHADIA MPO AND PR-3 ASSAYS, WHICH TESTED LOW POSITIVE FOR MPO AND NEGATIVE FOR PR-3. A BIOPSY WAS ORDERED (DATE UNKNOWN) BASED UPON THE PHADIA LOW POSITIVE MPO TEST RESULT. THE BIOPSY WAS POSITIVE FOR IGG ANTI-GLOMERULAR BASEMENT MEMBRANE (GBM) DISEASE. PLEX TREATMENT (PLASMA EXCHANGE) WAS ADMINISTERED FOLLOWING THE BIOPSY RESULTS. HOWEVER, THE CUSTOMER REPORTED THAT THE DELAY IN DIAGNOSIS LED TO IRREVERSIBLE DESTRUCTION OF ORGAN AND PERMANENT NEED FOR DIALYSIS.

    Patient problems: Kidney injury

    MAUDE report 21031210 ↗

Other System, Multipurpose For In Vitro Coagulation Studies devices

All System, Multipurpose For In Vitro Coagulation Studies devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page