Skip to content

Jagwire M00556560Recalls & reported problems

Boston Scientific Corporation · High Performance Guidewire · Class 2

All models of Jagwire (10)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 08714729858539), received between Dec 7, 2017 and Feb 23, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3
  • Break3
  • Detachment of Device or Device Component1
  • Device Contamination with Chemical or Other Material1
  • Peeled/Delaminated1
  • Unsealed Device Packaging1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient2
  • No Patient Involvement1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 23, 2026Unsealed Device Packaging; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT JAGWIRE WAS INSPECTED AT THE DISTRIBUTION FACILITY ON (B)(6) 2026. DURING THE INSPECTION, IT WAS REPORTED THAT THE STERILE SEAL OF THE DEVICE POUCH PEELED OFF. THE REPORTED EVENT MAY SUGGEST THAT THE STERILITY OF THE DEVICE HAS BEEN COMPROMISED. THERE WERE NO PATIENT INVOLVED IN THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24423723 ↗
  • MalfunctionJan 4, 2023Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A JAGWIRE WAS USED DURING A PANCREATIC STONE REMOVAL PROCEDURE PERFORMED ON (B)(6) 2022. DURING THE PROCEDURE, THE 3-5 MM TIP DETACHED WHILE SEEKING INSIDE THE PANCREATIC DUCT WITH A CANNULA AND WIRE, THE REMAINS WERE FOUND IN FLUOROSCOPIC IMAGES AND WAS SAFELY REMOVED FROM THE PANCREATIC DUCT. THE PROCEDURE WAS COMPLETED WITH A NON-BSC DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16096956 ↗
  • MalfunctionJun 29, 2022Break; Peeled/Delaminated; Adverse Event Without Identified Device or Use Problem; Break; Peeled/Delaminated; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A JAGWIRE GUIDEWIRE WAS USED IN THE BILE DUCT DURING A COMMON BILE DUCT STONE REMOVAL PROCEDURE ON (B)(6) 2022. DURING THE PROCEDURE, IT WAS CONFIRMED VIA ENDOSCOPY THAT A FEW MILLIMETERS OF THE COREWIRE TIP BROKE WHILE MANIPULATING THE GUIDEWIRE. THE TIP PART DETACHED IN DUODENUM AND REMAINED IN THE PATIENT BODY. THE PROCEDURE WAS COMPLETED WITH AN ENDOSELECTOR GUIDEWIRE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14856246 ↗
  • MalfunctionJun 19, 2018Break; Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A JAGWIRE¿ GUIDEWIRE WAS USED DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PROCEDURE PERFORMED ON (B)(6) 2018. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE, THE STENT WAS DEPLOYED CORRECTLY IN THE COMMON BILE DUCT. WHEN THE PHYSICIAN TRIED TO WITHDRAW THE DELIVERY SYSTEM , IT BECAME STUCK. THE STENT DID NOT MOVE WHEN THE DELIVERY SYSTEM WAS PULLED OUT. THE PHYSICIAN ENDED UP PULLING THE WIRE AND THE DELIVERY SYSTEM; HOWEVER, THE DELIVERY SYSTEM SNAPPED, LEAVING A PORTION OF THE WIRE IN THE DUCT. THEY WERE ABLE TO RETRIEVE A PIECE OF THE DELIVERY SYSTEM THAT BROKE OFF BY USING A FORCEPS BUT THE DISTAL OR FLOPPY TIP OF THE JAGWIRE REMAINED IN THE DUCT. REPORTED, THE STRICTURE WAS VERY TIGHT. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT DEVICE BY PLACING A 8X80 WALLFLEX BILIARY UNCOVERED STENT TO ENSURE PROPER DRAINAGE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT¿S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE. INVESTIGATION RESULTS REVEALED ON MAY 28, 2018 THAT THE CORE WIRE WAS BROKEN.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7615913 ↗
  • MalfunctionDec 20, 2017Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A JAGWIRE GUIDEWIRE WAS UNPACKED. ACCORDING TO THE COMPLAINANT, DURING UNPACKING, THERE WERE A LOT OF DUST SEEN INSIDE THE OUTER SHIPPING BOX, NOT INSIDE THE POUCH. THERE WAS NO PROCEDURE INVOLVED AND THE DEVICE WAS NOT USED IN THE PATIENT. INVESTIGATION RESULTS REVEALED ON (B)(6) 2017 THAT THERE WAS A FOREIGN MATERIAL INSIDE ONE OF THE POUCHES.

    Patient problems: No Patient Involvement

    MAUDE report 7135479 ↗
  • MalfunctionDec 7, 2017Break; Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT A JAGWIRE GUIDEWIRE WAS USED IN THE COMMON BILE DUCT DURING AN ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY (ERCP) PERFORMED ON (B)(6) 2017. ACCORDING TO THE COMPLAINANT, DURING THE PROCEDURE AS THE GUIDEWIRE WAS PULLED OUT, THE CORE WIRE WAS BROKEN AT THE LAST 3-4CM FROM THE TIP. THERE WAS A PART OF THE GUIDEWIRE THAT LEFT IN THE DUCT. THE PROCEDURE WAS COMPLETED WITH THIS DEVICE. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. THE PATIENT'S CONDITION AT THE CONCLUSION OF THE PROCEDURE WAS REPORTED TO BE FINE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7096615 ↗

FDA clearance and classification

The FDA regulates product code OCY (endoscopic guidewire, gastroenterology-urology) under 21 CFR 876.1500 as a Class II device. 21 CFR 876.1500 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Jagwire M00556560

Has the Jagwire M00556560 been recalled?

No FDA recall record in our data names this exact device identifier (DI 08714729858539), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Jagwire M00556560?

The FDA's MAUDE database lists 6 adverse event reports for this device, received between Dec 7, 2017 and Feb 23, 2026. In those reports, the most common specific device problems are “Break” (3), “Detachment of Device or Device Component” (1) and “Device Contamination with Chemical or Other Material” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Jagwire M00556560?

None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Jagwire M00556560 FDA approved?

Devices of this type (product code OCY) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Boston Scientific Corporation.

Who makes the Jagwire M00556560, and is it still sold?

The FDA's device database lists Boston Scientific Corporation as the company responsible for it (brand Jagwire, model M00556560). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Endoscopic guidewire, gastroenterology-urology devices

All Endoscopic guidewire, gastroenterology-urology devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page