DiRex™ Steerable Sheath M004DS50S0Recalls & reported problems
Oscor Inc. · Steerable sheath, 12F · Class 2
All models of DiRex Steerable Sheath (7)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 08714729858997), received between Jun 23, 2020 and May 3, 2022 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fluid/Blood Leak2
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Cardiac Tamponade1
- Heart Block1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
- Perforation of Vessels1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMay 3, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT UNDERWENT A PVC ABLATION PROCEDURE AND EXPERIENCED TWO DIFFERENT EVENTS. THE PATIENT EXPERIENCED A PERFORATION AND CARDIAC TAMPONADE. THE FIRST EVENT CAUSED A COMPLETE HEART BLOCK DURING A PVC ABLATION ON THE AORTIC CUSP. THE HEART BLOCK WAS CAUSED BY THE ABLATION OF LEFT SIDED PVC NEAR HIS. THE PATIENT RECEIVED A PACEMAKER AND WAS DISCHARGED. PT RECEIVED A TEMPORARY PACEMAKER AND WAS HELD OVER THE WEEKEND TO SEE IF CONDUCTION RETURNED. AN ORION CATHETER WAS USED TO MAP AND MIFI OI WAS USED DURING THE ABLATION AND THE SECOND EVENT CAUSED A PERFORATION OF THE LT ATRIUM DURING A TRANSEPTAL PUNCTURE. 1ST PUNCTURE WAS FINE AND USED ORION TO MAP LT ATRIUM. PHYSICIAN WAS UNABLE TO INSERT MEDTRONIC FREEZE SHEATH FOR CRYO ABLATION AND INSERTED A DIREX SHEATH INSTEAD. THE PHYSICIAN DIDN'T LIKE THE PLACEMENT OF THE FIRST PUNCTURE SO RE-INSERTED THE BRK NEEDLE THROUGH THE DIREX SHEATH AND PERFORATED THE LT ATRIUM. PATIENT HAD A TAMPONADE AND RECEIVED A PERICARDIOCENTESIS. PATIENT WAS STABLE AND WENT TO THE ICU. NO PATIENT OUTCOME: SERIOUS INJURY/ADVERSE PATIENT EFFECTS. DUE TO THE EVENTS AN ADDITIONAL SURGERY WAS PERFORMED. THERE WAS NO KNOWN DEVICE PROBLEM RE
Patient problems: Cardiac Tamponade; Heart Block; Perforation of Vessels
MAUDE report 14268643 ↗MalfunctionSep 3, 2021Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED PATIENT WAS UNHARMED AND PROCEDURE WAS COMPLETED. THE FAULTY DEVICE WAS BACK. DURING THE DEVICE ANALYSIS IT WAS FOUND THE HEMOSTATIC VALVE WAS TORN AND LEAKING. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12421556 ↗MalfunctionJun 23, 2020Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THE DIREX WAS REMOVED FROM THE PACKAGE AND WHEN BEING FLUSHED IT LEAKED FROM THE HANDLE WHERE THE TUBING ATTACHES. IT WAS USED FOR TREATMENT, HOWEVER SINCE THEY FOUND THE LEAK WHEN FLUSHING THE DIREX, IT WAS NEVER PUT INTO THE PATIENT. A NEW DIREX WAS PULLED AND USED WITH NO ISSUES. THE PATIENT WAS A MALE, APPROXIMATELY (B)(6), WEIGHT IS UNKNOWN. THE DIREX IS NOT BEING RETURNED FOR EVALUATION BECAUSE IT WAS LOST.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10183952 ↗
Other INTRODUCER, CATHETER devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page