Skip to content

EndoVive Standard PEG Kit M00509040Recalls & reported problems

Boston Scientific Corporation · Percutaneous Endoscopic Gastrostomy Kit ENFit · Class 2

All models of EndoVive Standard PEG Kit (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
1
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 08714729880462), received between May 7, 2022 and Nov 17, 2025 — classified as 1 death, 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Detachment of Device or Device Component1
  • Device Contaminated During Manufacture or Shipping1
  • Device Dislodged or Dislocated1
  • Difficult to Advance1
  • Migration1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Cardiac Arrest1
  • Insufficient Information1
  • Low Blood Pressure/ Hypotension1
  • Peritonitis1
  • Respiratory Arrest1
  • Respiratory Failure1
  • Sepsis1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 17, 2025Difficult to Advance; Difficult to Advance

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS ATTEMPTED TO BE USED DURING A PROCEDURE PERFORMED ON (B)(6) 2025. DURING THE PROCEDURE, IT WAS REPORTED THAT THE SURGEON COULD NOT GET THE DEVICE TO SLIDE OR OPERATE AT ALL. THE PEG ITSELF WAS NOT WORKING PROPERLY CAUSING THE SURGEON TO REQUEST A NEW ONE. ADDITIONAL CLARIFICATION REGARDING THE NATURE OF THE SERIOUS INJURY OR THE TYPE OF REQUIRED INTERVENTION WAS NOT PROVIDED. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS.

    Patient problems: Insufficient Information

    MAUDE report 23566442 ↗
  • MalfunctionMay 29, 2025Device Contaminated During Manufacture or Shipping; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS INSPECTED ON MAY 6, 2025. UPON INSPECTION, IT WAS REPORTED THAT A HAIR WAS INSIDE THE UNOPENED, STERILE DEVICE POUCH. IT WAS REPORTED THAT THERE WAS NO VISIBLE DAMAGE NOTED TO THE PACKAGING OF THE DEVICE. THERE WAS NO PATIENT OR PROCEDURE INVOLVED IN THIS EVENT. NOTE: A PHOTO OF THE COMPLAINT DEVICE WAS PROVIDED AND SHOWS A HAIR-LIKE PARTICLE ON THE TUBING OF THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22106471 ↗
  • InjuryMay 6, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS USED DURING A PERCUTANEOUS ENDOSCOPIC GASTROSTOMY TUBE PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2025. DURING THE PROCEDURE, THE TUBE BROKE WHILE BEING PULLED THROUGH THE ANTERIOR ABDOMINAL WALL. PART OF THE TUBE WAS LEFT IN THE PATIENT'S STOMACH. A LAPAROTOMY WAS PERFORMED TO RETRIEVE THE BROKEN TUBE AND PLACED A GASTROSTOMY TUBE. THERE WERE NO REPORTED PATIENT COMPLICATIONS AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21969567 ↗
  • InjuryOct 2, 2024Break; Break

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS USED IN THE STOMACH DURING AN ESOPHAGOGASTRODUODENOSCOPY (EGD) WITH PEG PLACEMENT PROCEDURE PERFORMED ON (B)(6) 2024. DURING THE PROCEDURE, MODERATE SEDATION WAS APPLIED TO THE PATIENT. IT WAS OBSERVED THAT THE PULL WIRE BROKE OFF AS IT WAS PULLED THROUGH THE INCISION. THE PHYSICIAN WAS UNABLE TO COMPLETE THE PROCEDURE, AND THE PEG TUBE REMAINED INSIDE THE PATIENT. THE PATIENT WAS TRANSFERRED TO A SHORT-TERM ACUTE CARE (STAC) HOSPITAL AND THE SAME PHYSICIAN COMPLETED THE PROCEDURE UNDER GENERAL ANESTHESIA. THE PEG TUBE WAS REMOVED AND REPLACED WITH A NEW PEG TUBE. IT WAS REPORTED THAT THE PATIENT WAS OKAY. THE PROCEDURE WAS COMPLETED WITH A DIFFERENT ENDOVIVE STANDARD PEG KIT. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20352350 ↗
  • MalfunctionSep 27, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS USED DURING A PERCUTANEOUS ENDOSCOPIC GASTROSTOMY (PEG) PLACEMENT PROCEDURE. THE EXACT PROCEDURE DATE WAS UNKNOWN. POST PROCEDURE, THE PEG TUBE THAT THE PHYSICIAN PLACED WAS DISLODGED. NO FURTHER INFORMATION HAS BEEN OBTAINED DESPITE GOOD FAITH EFFORTS. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20325140 ↗
  • DeathMay 7, 2022Migration; Migration

    IT WAS REPORTED TO BOSTON SCIENTIFIC CORPORATION THAT AN ENDOVIVE STANDARD PEG KIT PULL METHOD WAS USED DURING A PERCUTANEOUS ENDOSCOPIC GASTROSTOMY REPLACEMENT PROCEDURE (B)(6) 2021. THE PATIENT HAD AN INITIAL PEG TUBE PLACED ONE YEAR EARLIER AFTER BEING INJURED IN A MVC (MOTOR VEHICLE COLLISION). A SITTER IS REQUIRED TO PREVENT TUBE/IV MANUAL REMOVAL BY PATIENT WHO WAS CONFUSED. ON (B)(6) 2021, PROPER PLACEMENT OF TUBE WAS CONFIRMED VIA CAT (COMPUTERIZED AXIAL TOMOGRAPHY) SCAN AND PATIENT WAS TRANSFERRED FROM MEDICAL UNIT TO ICU (INTENSIVE CARE UNIT). PATIENT LATER DEVELOPED SYMPTOMS OF AN ACUTE ABDOMEN. DISTENDED ABDOMEN AND HYPOTENSION WERE NOTED. ON (B)(6) 2021, WHEN AN EXPLORATORY LAPAROTOMY WAS DONE TO REMOVE TUBE AND CLEAN OUT ABDOMEN. A GROSSLY ENLARGED LIVER WAS NOTED TO HAVE OVERLAPPED THE STOMACH, AND PEG TUBE HAD TRACT THROUGH LEFT LOBE OF LIVER. THE PEG WAS FOUND TO HAVE DISLODGED FROM STOMACH, RESULTING IN PERITONITIS. THE PEG TUBE WAS NOT RETAINED, HOWEVER THERE WAS NO REPORT FROM THE OPERATING ROOM TEAM WHO REMOVED THE PEG THAT THERE WERE ANY DEFECTS OR MISSING PARTS UPON EXTRACTION. NO EVIDENCE OF ANY DEVICE DEFECT. CONTINUED HYPOTENSION WAS NOTED POST OPERATIVE D

    Patient problems: Cardiac Arrest; Low Blood Pressure/ Hypotension; Peritonitis; Respiratory Arrest; Respiratory Failure; Sepsis

    MAUDE report 14317703 ↗

Other Gastrointestinal Tubes with Enteral Specific Connectors devices

All Gastrointestinal Tubes with Enteral Specific Connectors devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page