N/A M1091335VSRecalls & reported problems
AirLife Finland Oy · T-Piece Neonatal Patient Circuit Kit, Disposable · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10190752135680), received between Dec 28, 2022 and Mar 23, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Material Integrity Problem” (1 report).
3 other recalls cover devices cleared under the same FDA submission (K093913); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Integrity Problem1
- Pressure Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 23, 2024Material Integrity Problem; Material Integrity Problem
PEEP VALVE FAULTY. 3 CIRCUITS USED ON 2 DIFFERENT PANDA RESUSCITATORS WOULD ONLY PROVIDE 3 CMH2O OF PEEP DESPITE TURNING VALVE HIGHER AND HIGHER. RECEIVED MEDWATCH REPORT 0700220000-2023-8422.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18965564 ↗MalfunctionDec 28, 2022Pressure Problem
FOLLOWING PATIENT DELIVERY, TEAM ATTEMPTING TO GIVE PATIENT POSITIVE END-EXPIRATORY PRESSURE (PEEP) THROUGH T-PIECE RESUSCITATOR IN NEO ROOM. PER REPORT, PROVIDER UNABLE TO ACHIEVE PEEP GREATER THAN 7 AND HAD INSTANCES OF LOSING PEEP DURING PATIENT CARE. OF NOTE - THIS HAS BEEN REPORTEDLY HAPPENING WITH THIS PRODUCT RECENTLY AND CNS (REPORTER) IS WORKING WITH PRODUCT REP. AND SUPPLY CHAIN TO INVESTIGATE POTENTIAL PRODUCT CHANGE OR DEFECTS AFFECTING USE OF PRODUCT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16060740 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K093913. One submission often covers many models, so check the product and lot details in each record.
- Z-0821-2025 · Dec 10, 2024 · Open, ClassifiedNeo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842
- Z-0004-2025 · Aug 30, 2024 · Open, ClassifiedNeo-Tee T-Piece Resuscitator. Part Numbers 1050805, 1050832. For pediatric emergency respiratory support.
- Z-0639-2016 · Oct 22, 2015 · TerminatedMercury Medical Neo-Tee T-Piece Resuscitator and T-Piece Circuit. The Neo-Tee T-Piece Resuscitator is a gas powered emergency resuscitator intended to provide emergency respiratory
Other Ventilator, Emergency, Powered (Resuscitator) devices
- Pneupac P310NUSIcu Medical, Inc. · Ventilator, emergency, powered (resuscitator)4 deaths1,035 reports
- Pneupac 120003Icu Medical, Inc. · Ventilator, emergency, powered (resuscitator)2 deaths523 reports
- Neo-Tee T-Piece Resuscitator 10-50805Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)3 recalls0 reports
- Neo-Tee T-Piece Resuscitator 10-50811Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)2 recalls3 reports
- Neo-Tee T-Piece Resuscitator 10-50809Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)2 recalls0 reports
- Neo-Tee T-Piece Resuscitator 10-50810Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)2 recalls0 reports
- Neo-Tee T-Piece Resuscitator 10-50832Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)2 recalls0 reports
- Neo-Tee T-Piece Resuscitator 10-50808Mercury Enterprises, Inc. · Ventilator, Emergency, Powered (Resuscitator)2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page