VELA 16532-00 (UDI 10190752153325)Recalls & reported problems

Vyaire Medical, Inc. · VELA CF COMP,DISS,GRN O2,TYPE K,ENG OVERLAY · Class 2

All models of VELA (9)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 10190752153325), received between Jan 27, 2022 and Jun 14, 2024 — classified as 3 injuries, 11 malfunctions.

The most frequently reported specific device problem is “Failure to Calibrate” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 3 reportsMay 2024: 1 reportsJun 2024: 6 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520266
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Calibrate3
  • No Device Output3
  • Failure to Recalibrate2
  • Mechanical Problem2
  • Display or Visual Feedback Problem1
  • Failure to Conduct1
  • Gas/Air Leak1
  • High Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions14

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 14, 2024No Device Output; No Device Output

    ADDITIONAL INFORMATION RECEIVED INDICATES THAT A VYAIRE MEDICAL FSE WAS ABLE TO GO TO CUSTOMER SITE AND RESOLVE THE ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19537559 ↗
  • MalfunctionJun 13, 2024Failure to Conduct; Failure to Conduct

    IT WAS REPORTED TO VYAIRE MEDICAL: CUSTOMER TRIED TO CALIBRATE THE TRANSDUCERS WITH ONE FAILING. NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19531794 ↗
  • MalfunctionJun 12, 2024Failure to Calibrate; Failure to Calibrate

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VENT IS GIVING CONSTANT XDCR FAULT AFTER CALIBRATION. THERE WAS NO PATIENT INVOLVEMENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19518493 ↗
  • InjuryJun 11, 2024No Device Output; No Device Output

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VENTILATOR WENT INOPERABLE WHILE ON A PATIENT. THERE WAS NO PATIENT HARM REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19510217 ↗
  • MalfunctionJun 5, 2024Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED TO VYAIRE MEDICAL THAT INTERNAL LEAKING SOUND IS HEARD. NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19472307 ↗
  • InjuryJun 5, 2024No Device Output; No Device Output

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VENT WENT INOP. WHILE TRANSPORTING PATIENT WITHIN HOSPITAL. THEY WERE ABLE TO BAG THE PATIENT SO NO HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19472044 ↗
  • MalfunctionMay 9, 2024Failure to Calibrate; Failure to Calibrate

    IT WAS REPORTED TO VYAIRE MEDICAL A XDCR FAULT APPEARED ON THE VELA VENTILATOR DEVICE BY END USERS. NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19280133 ↗
  • MalfunctionApr 22, 2024Failure to Recalibrate; Failure to Recalibrate

    IT WAS REPORTED TO VYAIRE THAT TRANSDUCER FAULT OCCURRED WITH THE VELA VENTILATOR. FURTHERMORE, THE RESPIRATORY RATE WAS INCORRECT. THE EVENT OCCURRED DURING SETUP WITH NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19152293 ↗
  • MalfunctionApr 18, 2024Failure to Calibrate; Failure to Calibrate

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELAS TOUCH SCREEN IS NOT WORKING. NO PATIENT INVOLVEMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19137465 ↗
  • MalfunctionApr 16, 2024Failure to Recalibrate; Failure to Recalibrate

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELA HAD MOTOR FAULT, COIN CELL BATT ALARMS AND FAILING PM¿S. NO PATIENT INVOLVEMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19122036 ↗
  • MalfunctionMar 27, 2024High Readings; High Readings

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELA VENTILATOR WHEN PERFORMING THE BLENDER FIO2 (FRACTION OF INSPIRED OXYGEN) CALIBRATION IS GETTING VALUES OVER 100% AND CANNOT ADJUST PERMANENTLY DOWNWARD. THE CUSTOMER CONFIRMED THAT THERE IS NO PATIENT INVOLVEMENT ASSOCIATED WITH THIS REPORTED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18986112 ↗
  • MalfunctionJun 16, 2023Display or Visual Feedback Problem; Display or Visual Feedback Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELA VENTILATOR HAS A PROBLEM REGARDING DC (DIRECT CURRENT) INDICATOR LED (LIGHT-EMITTING DIODE) THAT IS DIM. FURTHERMORE, THERE IS NO PATIENT INVOLVEMENT ASSOCIATED WITH THE REPORTED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17145000 ↗
  • InjuryJan 30, 2023Mechanical Problem; Mechanical Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELA VENTILATOR HAS TRANSDUCER FAULT DURING PATIENT USE. THERE IS NO PATIENT HARM REPORTED. PATIENT WAS PLACED ON ANOTHER VENTILATOR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16268537 ↗
  • MalfunctionJan 27, 2022Mechanical Problem; Mechanical Problem

    IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VELA VENTILATOR IS PRESENTING WITH OXYGEN RANGE ERROR. THE CUSTOMER CONFIRMED THERE WAS NO PATIENT INVOLVEMENT ASSOCIATED WITH THE REPORTED EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13367091 ↗

Other Ventilator, continuous, facility use devices

All Ventilator, continuous, facility use devices →