Revel 19260-001Recalls & reported problems
Vyaire Medical, Inc. · REVEL Ventilator · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10190752157071), received between Apr 18, 2024 and Jun 24, 2024 — classified as 3 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Gas/Air Leak” (2 reports).
15 other recalls cover devices cleared under the same FDA submission (K103211); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Gas/Air Leak2
- Incorrect Measurement1
- Incorrect, Inadequate or Imprecise Result or Readings1
- Intermittent Infusion1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 24, 2024Gas/Air Leak; Gas/Air Leak
ADDITIONAL INFORMATION RECEIVED INDICATES THAT THE VENTILATOR WAS RETURNED AND EVALUATED IN THE FA LAB. THE REPORTED COMPLAINT WAS VERIFIED AND DUPLICATED. THIS IS ISOLATED TO INCORRECT MAINTENANCE AND DEVICE MISUSE WITH THE 3 SCREWS ON THE O2 INLET PORT WHICH WERE NOT TORQUED TO SPECIFICATIONS AND THE DAMAGED O-RING CAUSES THE LEAK FROM THE O2 BLENDER MODULE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19594072 ↗InjuryJun 21, 2024Intermittent Infusion; Intermittent Infusion
IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VENTILATOR HAD A DAMAGED POWER PIGTAIL AND WAS GIVING THE PATIENT INTERMITTENT BIPAP BREATHS "VENT WAS ON THE PATIENT. IT SEEMED TO BE WORKING FINE, THEN JUST STOPPED DELIVERING A BREATH, REPEATEDLY WHILE WE WERE TROUBLESHOOTING. THE PATIENT WAS SIGNALING THAT SHE COULDN'T GET A BREATH, WE TRIED TROUBLESHOOTING IT AND ON THE THIRD TIME WE REMOVED IT AND PUT HER ON FLOW DRIVEN CPAP." NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19583667 ↗InjuryMay 22, 2024Gas/Air Leak; Gas/Air Leak
IT WAS REPORTED TO VYAIRE MEDICAL, THE BLOWER DEMAND EXCEEDED ALARM OCCURRED WHILE TRANSPORTING A PATIENT. PATIENT INVOLVED, BUT NO HARM OR INJURY TO PATIENT. TRACH PATIENT WAS PUT ON ANOTHER VENTILATOR WITH NO FURTHER ISSUES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19370745 ↗InjuryMay 9, 2024Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
IT WAS REPORTED TO VYAIRE MEDICAL THAT THE UNIT RUNNING ON A PATIENT DURING A TRANSPORT. THIS UNIT WAS RUNNING ON THE PATIENT ON VOLUME AC, VT 450, RATE 18. IT WAS NOTICED THE RESPIRATORY RATE ON THEIR EXTERNAL ETCO2 MONITOR WAS READING 12-14 CONSISTENTLY. THEY ARE AWARE THIS IS AN EXTERNAL MONITOR, NOT THE VENT. THE VENT WAS READING 18 AS WELL. THEY TOOK THE UNIT ASIDE AFTER THE TRANSPORT AND HAD THE RATE STILL SET TO 18 AND TIMED THE BREATHS WITH A WATCH AND GOT 12 BREATHS PER MINUTE. NO PATIENT HARM WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19282392 ↗MalfunctionApr 18, 2024Incorrect Measurement; Incorrect Measurement
IT WAS REPORTED TO VYAIRE MEDICAL THAT THE VENTILATOR IS NOT GENERATING VOLUME. NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19133535 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K103211. One submission often covers many models, so check the product and lot details in each record.
- Z-1890-2016 · May 17, 2016 · TerminatedAVEA Standard with Compressor ventilator, 17312-xx (xx = 0 - 14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering
- Z-1891-2016 · May 17, 2016 · TerminatedAVEA Comprehensive ventilator-refurbished, R17310-xx (xx = 0-14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering
- Z-1892-2016 · May 17, 2016 · TerminatedAVEA Standard ventilator-refurbished, R17311-xx (xx = 0-14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a pred
- Z-1894-2016 · May 17, 2016 · TerminatedTCA Board, 16542A A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined percentage of oxygen in the brea
- Z-1898-2016 · May 17, 2016 · TerminatedAVEA GDE/UIM upgrade kit, 12283-PMN A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined percentage of
- Z-1889-2016 · May 17, 2016 · TerminatedAVEA Standard ventilator, 17311-xx (xx = 0 - 14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined
- Z-1899-2016 · May 17, 2016 · TerminatedAVEA GDE upgrade kit, 12284-PMN A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined percentage of oxyg
- Z-1893-2016 · May 17, 2016 · TerminatedAVEA Standard with Compressor ventilator-refurbished, R17312-xx (xx = 0-14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by d
- Z-1897-2016 · May 17, 2016 · TerminatedGas Delivery Engine (GDE)-refurbished, R16650A A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined per
- Z-1888-2016 · May 17, 2016 · TerminatedAVEA Comprehensive ventilator, 17310-xx (xx = 0 - 14) A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predeter
- Z-1895-2016 · May 17, 2016 · TerminatedGas Delivery Engine (GDE)-1st Generation, 16222-001-99 A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predeterm
- Z-1896-2016 · May 17, 2016 · TerminatedGas Delivery Engine (GDE), 16650A A continuous ventilator intended to mechanically control or assist broad spectrum patient breathing by delivering a predetermined percentage of ox
- Z-1609-2015 · Apr 3, 2015 · TerminatedCareFusion AVEA ventilator, all models. Product Usage: A continuous ventilator (respirator), intended to mechanically control or assist patient breathing by delivering a predeterm
- Z-2273-2013 · Sep 5, 2013 · TerminatedProduct Name: AVEA Ventilator. All Models. The affected devices are cleared under K073069 pm 1/25/2008 and K103211 on 05/06/2011. This device is a Class II medical Device. A cont
- Z-0510-2012 · Sep 8, 2011 · TerminatedAVEA Ventilator (Catalog Code 17310, 17311, 17312). The AVEA is intended to provide continuous respiratory support in an institutional health care environment (e.g. hospitals). It
Other Ventilator, Continuous, Facility Use devices
- Trilogy Trilogy100 Ventilator, United StatesRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE92 deaths8,161 reports
- Trilogy Evo Trilogy Evo, USARespironics, Inc. · Ventilator, continuous, facility use6 recalls50 deaths4,393 reports
- Trilogy 100 Trilogy 100 W/ Bluetooth, USARespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE65 deaths4,569 reports
- CARESCAPE R860Datex-Ohmeda Inc · VENTILATOR, CONTINUOUS, FACILITY USE1 recall1 death4,346 reports
- HAMILTON-C1 161001Hamilton Medical AG · Ventilator, Continuous, Facility Use2 recalls12 deaths1,849 reports
- Trilogy Trilogy O2 Ventilator JapanRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE7 deaths1,900 reports
- Trilogy Trilogy 202 Ventilator InternationalRespironics, Inc. · VENTILATOR, CONTINUOUS, FACILITY USE11 deaths1,564 reports
- HAMILTON-C6 160021Hamilton Medical AG · Ventilator, Continuous, Facility Use5 recalls10 deaths1,175 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page