Skip to content

MEDLINE MDTSUPRAAIRRecalls & reported problems

Medline Industries, Inc. · MATTRESS,SYSTEM,SUPRA AIR,LAL · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10197344102549), received between Jul 20, 2026 and Sep 28, 2026 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Unintended Deflation” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 2 reportsSep 2026: 4 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unintended Deflation5
  • Delayed Alarm1
  • Inflation Problem1
  • Pumping Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 28, 2026Unintended Deflation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50925257 ↗
  • MalfunctionSep 24, 2026Inflation Problem

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50891273 ↗
  • MalfunctionSep 9, 2026Unintended Deflation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50699533 ↗
  • MalfunctionSep 1, 2026Delayed Alarm; Unintended Deflation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50546605 ↗
  • MalfunctionAug 31, 2026Pumping Problem

    It was reported that "the new pump might be having some issues as it seems like my body is sinking into the mattress more than usual again."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50525304 ↗
  • MalfunctionAug 10, 2026Unintended Deflation

    It was reported that the mattress does not hold air.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50194416 ↗
  • MalfunctionJul 20, 2026Unintended Deflation

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25881279 ↗

Other Mattress, air flotation, alternating pressure devices

All Mattress, air flotation, alternating pressure devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page