The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10351688506597), received between Dec 21, 2020 and Apr 9, 2026 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Backflow1
  • Fluid/Blood Leak1
  • Leak/Splash1
  • Material Separation1

Patient problems

  • Bradycardia2
  • High Blood Pressure/ Hypertension2
  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 9, 2026Leak/Splash

    IT WAS STATED THAT THE IV EXTENSION PIECE CRACKED, AND BLOOD BACKED UP IN THE LINE. PATIENT WAS AFFECTED. THE LINE HAD BEEN RUNNING TPN AND LIPIDS FOR ABOUT 12 HOURS BEFORE IT CRACKED. THERE WAS NO HARM TO THE PATIENT, AND THEY CONTACTED THE RESPONSIBLE PERSON. NO MONITORING WAS REQUIRED. THE EVENT WAS RESOLVED. THE PATIENT WAS A 5-MONTH-OLD WHITE/CAUCASIAN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24830336 ↗
  • MalfunctionNov 6, 2023Backflow; Fluid/Blood Leak; Material Separation; Backflow; Fluid/Blood Leak; Material Separation

    IT WAS REPORTED THAT THE REGISTERED NURSE NOTICED THAT BLOOD WAS BACKING UP IN CATHETER TUBING. IT WAS THEN NOTICED THAT BLOOD WAS DRIPPING FROM THE TUBING. WHILE DOING THE ALCOHOL SCRUB, THE TUBING FELL APART ("BROKE IN AT END, NEAR CONNECTION"). ADVERSE EFFECTS HAVE NOT BEEN REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 18075113 ↗
  • InjuryDec 21, 2020Break; Break

    ADDITIONAL INFORMATION WAS PROVIDED DETAILING THAT NO ACLS MEDS WERE GIVEN. THE PATIENT'S VITALS NORMALIZED AFTER ECMO FLOWS WERE RESTORED.

    Patient problems: Bradycardia; High Blood Pressure/ Hypertension

    MAUDE report 11052031 ↗
  • InjuryDec 21, 2020Break; Break

    INFORMATION WAS RECEIVED INDICATING THAT A SMITHS MEDICAL TUBING PIGTAIL BROKE OFF AT THE CRRT ACCESS SITE (PRE STOPCOCK) WHILE HOISTING THE PATIENT UP IN THE BED. THERE WAS NO NOTICED STRETCHING OF THE PLASTIC TO MAKE THE TUBING BREAK. THE PIGTAIL WAS SHOOTING BLOOD OUT OF THE ECMO CIRCUIT ONTO THE BED AND FLOOR. IT WAS CLAMPED OFF TO STOP BLEEDING. A NEW PIGTAIL AND STOPCOCK WERE PRIMED TO RESOLVE THE EVENTS. PATIENT WAS CLAMPED OFF ECMO FOR 20 SECONDS WHILE A NEW PIGTAIL WAS PLACED. PATIENT BECAME BRADYCARDIC INTO THE 30'S, AND HYPERTENSIVE. THERE WERE NO OTHER ADVERSE EVENTS REPORTED.

    Patient problems: Bradycardia; High Blood Pressure/ Hypertension